![ABB ACS310 Скачать руководство пользователя страница 146](http://html.mh-extra.com/html/abb/acs310/acs310_user-manual_2963146.webp)
146 Program features
It is also possible to monitor motor temperature by connecting a PTC sensor and
a thermistor relay between the +24 V DC voltage supply offered by the drive and a
digital input. The figure below displays the connection.
WARNING!
According to IEC 664, the connection of the motor thermistor to the
digital input requires double or reinforced insulation between motor live parts
and the thermistor. Reinforced insulation entails a clearance and creeping distance of
8 mm (400/500 V AC equipment).
If the thermistor assembly does not fulfill the requirement, the other I/O terminals of
the drive must be protected against contact, or a thermistor relay must be used to
isolate the thermistor from the digital input.
Settings
Diagnostics
Parameter
Additional information
Analog input settings
Analog output settings
Motor temperature measurement settings
Other
At the motor end the cable shield should be grounded through, eg a 3.3 nF capacitor. If this is
not possible, the shield is to be left unconnected.
Actual signal
Additional information
Motor temperature
Alarm/Fault
Additional information
/
Excessive motor temp
T
Thermistor
relay
DI1…5
+24 V DC
Motor
Par.
= THERM (0) or THERM(1)
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182