9.5 Actual signals mode
Two displays can be selected in the actual signals mode:
9.5.1 Overview
Two kinds of displays can be selected in the actual
signals mode:
• Actual signals display
• Fault history display
The actual signals display appears first when the
actual signals display mode has been selected.
However, when the drive is in a fault condition, the
fault display will be shown instead.
The actual signals display is used to monitor the
drive without interfering its operation. Three
selectable actual values are shown continuously on
the display.
The CDP control panel will automatically return to
the actual signals
mode from other modes within
one minute when no keys are pressed (exceptions:
status display and common reference display when
in drive selection and fault display mode).
Actual values
Fault memory
The fault memory includes information on the 64
most recent fault events that occurred in the drive.
The name of the fault and the actual time are dis-
played. The procedure for selecting and clearing
the fault history is described in section
playing and resetting an active fault
When a fault or warning is generated in the drive,
the message will be displayed immediately, except
when in
drive selection mode.
Changing from the fault display mode to other dis-
play modes is possible without resetting the fault
first. When no keys are pressed, the fault or warn-
ing text is displayed as long as the fault is pending.
Control panel overview
Status line
Actual signal names and values
Selects the function mode
Selects actual signals and faults
Scrolls through signal and fault messages
Enters the selection mode
Acknowledges the selection
9.5.2 Selecting the actual signals display
To open the actual signals display, press the ACT
key.
Group 01
Measured or calculated motor values
Group 02
Measured or calculated drive values
Group 03
Reference values
Group 04
I/O status signals
Group 05
Communication link and
MCB status signals
Group 06
Software version, drive and motor nominal
values
Group 07
Control words
Group 08
Status words
Group 09
Fault and alarm words
!
For the complete list of selectable actual
signals, see
Signal and parameter table
1 L ->
600.0 rpm
StateINU
ReadyOn
MOTOR SP
0.00 rpm
POWER
0.0 kW
1
2
3
4
5
6
1
2
3
4
5
6
1 L ->
600.0 rpm
StateINU
ReadyOn
MOTOR SP
0.00 rpm
POWER
0.0 kW
Содержание ACS2000 AFE 2MVA
Страница 8: ...General information on manual and equipment ...
Страница 13: ...13 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Страница 14: ...Terms abbreviations trademarks ...
Страница 19: ...19 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Страница 20: ...Important note on main circuit breaker ...
Страница 48: ...Chapter 3 Control system 49 Control unit 50 Main components 55 I O interfaces ...
Страница 69: ...69 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Страница 111: ...111 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Страница 118: ...Commissioning check list ...
Страница 153: ...153 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Страница 180: ......