Parameters 115
Diagnostic word 1. For possible causes and remedies,
see chapter
0b0000
0b0000…0b1111
Diagnostic word 1.
1 = 1
Diagnostic word 2. For possible causes and remedies,
see chapter
0b0000
0b0000…0b1111
Diagnostic word 2.
1 = 1
Diagnostic word 3. For possible causes and remedies,
see chapter
0b0000
0b0000…0b1111
Diagnostic word 3.
1 = 1
Displays the motor speed (
) at which fault occurred.
-
-30000.00…
30000.00 rpm
Motor speed at fault.
See par.
Displays the output frequency (
) at which fault
occurred.
-
-500.00…500.00 Hz
Output frequency at fault.
See par.
Displays the DC link volt age (
) at which fault
occurred.
-
0.00…2000.00 V
DC voltage at fault.
10 = 1 V
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Value
0
Any warning or fault
Yes = Drive has generated a warning or tripped on a fault.
1
Any warning
Yes = Drive has generated a warning.
2
Any fault
Yes = Drive has tripped on a fault.
3
Reserved
4
Overcurrent fault
Yes = Drive has tripped on fault
5
Reserved
6
DC overvoltage
Yes = Drive has tripped on fault
.
7
DC undervoltage
Yes = Drive has tripped on fault
.
8
Reserved
9
Device overtemp flt
Yes = Drive has tripped on fault
.
10...15 Reserved
Bit
Name
Value
0...9
Reserved
10
Motor overtemp flt
Yes = Drive has tripped on fault
.
11…15 Reserved
Bit
Name
Value
0...8
Reserved
9
kWh pulse
1 = kWh pulse is active.
10
Reserved
11
Fan command
1 = Drive fan is rotating above idle speed.
12…15 Reserved
ACS180 FW.book Page 115 Tuesday, March 9, 2021 2:25 PM