Basic signals for monitoring of the drive.
01.02
SPEED
Calculated motor speed in rpm. Filter time setting with parameter
MOTOR SP FILT TIM.
-20000 =
-100% 20000
= 100% of
motor abs.
max. speed
01.03 FREQUENCY
Calculated
drive
output frequency.
-100 = -1 Hz
100 = 1 Hz
01.04
CURRENT
Measured motor current.
10 = 1 A
01.05
TORQUE
Calculated motor torque. 100 is the motor nominal torque. Filter time
setting with parameter
TORQ ACT FILT TIM.
-10000 =
-100% 10000
= 100% of
motor nom.
torque
01.06
POWER
Motor power. 100 is the nominal power.
-1000 =
-100% 1000 =
100% of motor
nom. power
01.07
DC BUS VOLTAGE V
Measured intermediate circuit voltage.
1 = 1 V
01.08
MAINS VOLTAGE
Calculated supply voltage.
1 = 1 V
01.09
OUTPUT VOLTAGE
Calculated motor voltage.
1 = 1 V
01.10
ACS800 TEMP
Calculated IGBT temperature.
1 = 1 °C
01.11
EXTERNAL REF 1
External reference REF1 in rpm. (Hz if value of parameter
MOTOR
CTRL MODE is SCALAR.)
1 = 1 rpm
01.12
EXTERNAL REF 2
External reference REF2.
Depending on the use, 100% is the motor
maximum speed, motor nominal torque, or maximum process reference.
0 = 0% 10000
= 100% 1)
01.13
CTRL LOCATION
Active control location. (1,2) LOCAL; (3) EXT1; (4) EXT2. See section
Local control vs. external control
.
See descr.
01.14
OP HOUR COUNTER
Elapsed time counter. Runs when the control board is powered.
1 = 1 h
01.15
KILOWATT HOURS
kWh counter. Counts inverter output kWh during operation (motor side -
generator side).
1 = 100 kWh
01.17
DIL DI6-1 STATUS
Status of digital inputs.
Example:
0000001 = DI1 is on, DI2 to DI6 and
DIL are off.
01.18
AI1 [V]
Value of analogue input AI1.
1 = 0.001 V
01.19
AI2 [mA]
Value of analogue input AI2.
1 = 0.001 mA
01.20
AI3 [mA]
Value of analogue input AI3.
1 = 0.001 mA
01.21
RO3-1 STATUS
Status of relay outputs.
Example:
001 = RO1 is energised, RO2 and
RO3 are de-energised.
01.22
AO1 [mA]
Value of analogue output AO1.
1 =0.001 mA
01.23
AO2 [mA]
Value of analogue output AO2.
1 = 0.001 mA
01.27
APPLICATION MACRO
Active application macro (value of parameter
).
01.28
EXT AO1 [mA]
Value of output 1 of the analogue I/O extension module (optional).
1 = 0.001 mA
01.29
EXT AO2 [mA]
Value of output 2 of the analogue I/O extension module (optional).
1 = 0.001 mA
01.30
PP 1 TEMP
Measured heatsink temperature in inverter no. 1.
1 = 1°C
01.31
PP 2 TEMP
Measured heatsink temperature in inverter no. 2 (used only in high power
units with parallel inverters).
1 = 1 °C
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...