Installation and Start-up Guide for NBRA-6xx
3-1
Chapter 3 – Voltage Selection and
Mechanical Installation
Overview
This chapter contains braking chopper voltage selection instructions
and mechanical installation instructions. The voltage selection for the
NBRA-6xx is described on the first page of the chapter. The procedure
is the same for all the choppers. Mechanical installation instructions are
given separately for each chopper type starting from page 3-3.
Note:
Drive Parameter 20.5 (20.7 for ACP 600) OVERVOLTAGE CTRL
must be set to OFF to enable chopper operation.
Voltage Selection
The voltage level must be selected before the braking chopper is
mounted. The voltage is set, according to the mains voltage, with a
jumper on the chopper control board. (The front cover of the chopper
has to be removed to access the jumper.)
CAUTION!
Incorrect jumper setting or missing jumper may cause
braking chopper malfunctioning or damage to the chopper or resistor.
Figure 3-1 Braking chopper voltage selection.
FI
B
E
R
230V
400V
500V
ACS 600 mains voltage
380 to 415 V
ACS 600 mains voltage
440 to 500 V
Chopper controlled by
another chopper (see
Figure 3-2)
FI
B
E
R
230V
400V
500V
FI
B
E
R
ACS 600 mains voltage
525 to 690 V
FI
B
E
R
230V
400V
>
500V
230V
400V
500V
Содержание ACS 600
Страница 1: ...ACS 600 Installation and Start up Guide NBRA 6xx Braking Choppers ...
Страница 2: ......
Страница 4: ......
Страница 10: ...Chapter 1 Introduction to This Guide 1 2 Installation and Start up Guide for NBRA 6xx ...
Страница 18: ...Chapter 2 Overview 2 8 Installation and Start up Guide for NBRA 6xx ...
Страница 46: ...Chapter 5 Fault Tracing 5 2 Installation and Start up Guide for NBRA 6xx ...
Страница 53: ......