Motor control and I/O board (RMIO)
RMIO board specifications
Analog inputs
With Pump Control Program two programmable differential current inputs (0 mA /
4 mA to 20 mA,
R
in
= 100 ohm) and one programmable differential voltage input
(-10 V / 0 V / 2 V to +10 V,
R
in
> 200 kohm).
The analog inputs are galvanically isolated as a group.
Isolation test voltage
500 V AC, 1 min
Max. common mode voltage
between the channels
±15 V DC
Common mode rejection ratio
> 60 dB at 50 Hz
Resolution
0.025 % (12 bit) for the -10 V to +10 V input. 0.5 % (11 bit) for the 0 to +10 V and 0 to
20 mA inputs.
Inaccuracy
±
0.5 % (Full Scale Range) at 25
°
C (77
°
F). Temperature coefficient: ± 100 ppm/
°
C
(± 56 ppm/°F), max.
Constant voltage output
Voltage
+10 V DC, 0, -10 V DC ± 0.5 % (Full Scale Range) at 25 °C (77
°
F). Temperature
coefficient: ± 100 ppm/°C (± 56 ppm/°F) max.
Maximum load
10 mA
Applicable potentiometer
1 kohm to 10 kohm
Auxiliary power output
Voltage
24 V DC ± 10 %, short circuit proof
Maximum current
250 mA (shared between this output and optional modules installed on the RMIO)
Analog outputs
Two programmable current outputs: 0 (4) to 20 mA,
R
L
< 700 ohm
Resolution
0.1 % (10 bit)
Inaccuracy
±
1 % (Full Scale Range) at 25
°
C (77
°
F). Temperature coefficient: ± 200 ppm/
°
C
(± 111 ppm/
°
F) max.
Digital inputs
With Pump Control Program six programmable digital inputs (common ground: 24 V
DC, -15 % to +20 %) and a start interlock input. Group isolated, can be divided in two
isolated groups (see
Isolation and grounding diagram
below).
Thermistor input: 5 mA, < 1.5 kohm
“1” (normal temperature), > 4 kohm
“0”
(high temperature), open circuit
“0” (high temperature).
Internal supply for digital inputs (+24 V DC): short circuit proof. An external 24 V DC
supply can be used instead of the internal supply.
Isolation test voltage
500 V AC, 1 min
Logical thresholds
< 8 V DC
“0”, > 12 V DC
“1”
Input current
DI1 to DI 5: 10 mA, DI6: 5 mA
Filtering time constant
1 ms
Содержание ACQ800 Series
Страница 1: ...Hardware Manual ACQ800 37 Drives 55 to 450 kW 75 to 550 hp ACQ800 ...
Страница 4: ......
Страница 12: ...12 ACQ800 37 Hardware Manual Safety instructions ...
Страница 24: ...24 ACQ800 37 Hardware Manual About this manual ...
Страница 52: ...52 ACQ800 37 Hardware Manual Mechanical installation ...
Страница 78: ...78 ACQ800 37 Hardware Manual Electrical installation ...
Страница 84: ...84 ACQ800 37 Hardware Manual Motor control and I O board RMIO ...
Страница 92: ...92 ACQ800 37 Hardware Manual Installation checklist and start up ...
Страница 106: ...106 ACQ800 37 Hardware Manual Maintenance 3 4 5 6 8 7b 7a ...
Страница 107: ...ACQ800 37 Hardware Manual 107 Maintenance 9 10 11 View from back ...
Страница 123: ...ACQ800 37 Hardware Manual 123 Technical data Declaration of Conformity ...
Страница 124: ...124 ACQ800 37 Hardware Manual Technical data ...
Страница 128: ...128 ACQ800 37 Hardware Manual Dimensions Frame R6 ...
Страница 129: ...ACQ800 37 Hardware Manual 129 Dimensions Frame R6 continued ...
Страница 130: ...130 ACQ800 37 Hardware Manual Dimensions Frame R7i ...
Страница 131: ...ACQ800 37 Hardware Manual 131 Dimensions Frame R7i continued ...
Страница 132: ...132 ACQ800 37 Hardware Manual Dimensions Frame R7i continued ...
Страница 133: ...ACQ800 37 Hardware Manual 133 Dimensions Frame R7i continued ...
Страница 134: ...134 ACQ800 37 Hardware Manual Dimensions Frame R8i ...
Страница 135: ...ACQ800 37 Hardware Manual 135 Dimensions Frame R8i continued ...
Страница 136: ...136 ACQ800 37 Hardware Manual Dimensions Frame R8i continued ...
Страница 137: ...ACQ800 37 Hardware Manual 137 Dimensions Frame R8i continued ...
Страница 138: ...138 ACQ800 37 Hardware Manual Dimensions ...