78 Start-up and control
Start-up the drive
The start-up procedure includes tasks performed only when the drive is powered up
for the first time (for example, entering the motor data). After the first start-up, the
drive can be powered up without using these start-up tasks. The procedure can be
repeated later if start-up data needs to be changed.
In addition to the drive power-up, the procedure includes the following tasks:
• entering the motor data and performing the motor identification run
• setting up the encoder
• checking the Safe torque off circuits
• setting up the motor overtemperature protection
• setting up the following elevator control functions:
•
Start/stop control
•
Mechanical brake control
•
Speed reference scaling
•
Speed reference selection
•
Acceleration/deceleration selection
•
Jerk selection.
If an alarm or a fault is generated during the start-up, see section
for the possible causes and remedies. If problems continue, disconnect the
main power and wait 5 minutes for the intermediate circuit capacitors to discharge
and check the drive and motor connections.
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...