218 Parameters
10.87
LIFT CW
Lift control word for fieldbus control.
0x0000/
0x0000…0xFFFF Control word.
- / 1 = 1
10.88
EVAC REC CUR
LIM
Defines the recommended evacuation current limit.
0...100 %
Evacuation current limit.
1 = 1
10.89
EVAC REC DIR
MEM
Shows the recommended evacuation direction.
FORWARD/
FORWARD
Forward direction
0
BACKWARD
Reverse direction
1
12
12 DIGITAL IO
Settings for the digital inputs and outputs, and the
relay output.
12.01
DIO1 CONF
Selects whether DIO1 is used as a digital input or as
a digital output.
Input/
Output
DIO1 is used as a digital output.
0
Input
DIO1 is used as a digital input.
1
12.02
DIO2 CONF
Selects whether DIO2 is used as a digital input, as a
digital output or as a frequency input.
Output/
Output
DIO2 is used as a digital output.
0
Input
DIO2 is used as a digital input.
1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Value Information
0
START UP
1
Start command is active in the upward direction.
0
Start command is inactive in the upward direction.
1
START DOWN 1
Start command is active in the downward direction.
0
Start command is inactive in the downward direction.
2
INSPECT
START UP
1
Inspection mode is enabled in the upward direction.
0
Inspection mode is disabled in the upward direction.
3
INSPECT
START DN
1
Inspection mode is enabled in the downward direction.
0
Inspection mode is disabled in the downward direction.
4
SPEED REF
SEL1
1
Speed selection bit 1 is enabled.
0
Speed selection bit 1 is disabled.
5
SPEED REF
SEL2
1
Speed selection bit 2 is enabled.
0
Speed selection bit 2 is disabled.
6
SPEED REF
SEL3
1
Speed selection bit 3 is enabled.
0
Speed selection bit 3 is disabled.
7
RUN ENABLE
1
Run enable signal is active.
0
Run enable signal is inactive.
8
FAULT RESET 1
Fault reset signal is active.
0
Fault reset signal is inactive.
9…15
NOT USED
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...