If the turbocharger has been operated for a longer period of time outside the admissible
range, ABB Turbocharging recommends having the turbocharger inspected by an ABB Tur-
bocharging Service Station.
4.1.1
Pre-lubrication and post-lubrication
CAUTION
Pre-lubrication
Serious damage to engine or property can result if the turbocharger is not
supplied with oil from the first moment after starting the engine.
u
Activate the pre-lubrication device each time before starting the engine.
The pre-lubrication time is at least 5 minutes.
The post-lubrication time is at least 10 minutes.
If the engine is operated for 5 to 10 minutes in idle mode before stopping, no additional
post-lubrication is required.