Sodium Monitoring

in Water Treatment Processes

Application Guide

AG/AI–024_4

Cation Bed

Reduction of

positively

charged

dissolved

solids

Anion

Exchange

Bed

Reduction of

negatively

charged

dissolved

solids

Mixed Bed

Further reduction
of  any remaining

concentrations of

both positively and

negatively

charged dissolved

solids to produce pure

water

Raw

Water

In

High Purity
Water Out

8037 Sodium Monitor

Typical Range: 0.1ppb to 10ppm

Normal sodium concentration: 100ppb

(dependent upon type of exchange and
raw water quality)

8037 Sodium Monitor

Typical Range: 0.01ppb to 1.0ppm

Normal sodium concentration: 1.0ppb

Sample

to

sodium

Monitor

Sample

to

sodium

Monitor

The illustration above shows a simple demineralisation
plant where anions are exchanged with hydroxyl ions
and cations are exchanged with hydrogen ions

(by the use of ion exchange resins) to produce pure,
mineral-free water. ABB sodium monitors are used
for continuous monitoring of sodium in the process
water.

Содержание 8037

Страница 1: ...8037 Sodium Monitor Typical Range 0 1ppb to 10ppm Normal sodium concentration 100ppb dependent upon type of exchange and raw water quality 8037 Sodium Monitor Typical Range 0 01ppb to 1 0ppm Normal sodium concentration 1 0ppb Sample to sodium Monitor Sample to sodium Monitor The illustration above shows a simple demineralisation plant where anions are exchanged with hydroxyl ions and cations are e...

Страница 2: ...onal maintenance normally required by such systems We supply full details of reagents to ensure the most cost effective procurement options Our integral constant head design eliminates the effects of sample pressure and flow rate variations and minimises sample transport time Our patented calibration solution technique ensures thermal equilibrium In addition ABB offer greater security at a lower c...

Страница 3: ...nt Plant on a rack preferably in an air conditioned room Samples are normally at ambient temperatures so sample cooling should not be necessary even the polishing plant will be below 55 C Fit a needle valve upstream to control the sample flow within required limits Conveniently site the standard solution bottles on the top of the liquid handling section of the monitor Simplified schematic of once ...

Страница 4: ...solids content and thus produce the quality of make up water required Condensate Polishing Plant CPP This type of plant is used mainly on once through type boilers It takes the condensate from the steam turbine condenser and purifies or polishes it to reduce the concentrations of any impurities such as sodium chloride sulphate etc which may have entered the system via condenser tube leaks Condensa...

Страница 5: ... County Line Road Warminster PA 18974 USA Tel 1 215 674 6000 Fax 1 215 674 7183 ABB has Sales Customer Support expertise in over 100 countries worldwide www abb com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice Printed in UK 12 03 ABB 2003 ...

Отзывы: