82
“Operation and installation manual”
EN
11.4 Prefabricated foundation - Terra 360
The drawing shows all the necessary measurements of the prefabricated foundation:
NOTE
On the top side of the prefabricated foundation an arrow indicates the front side.
NOTE
Each side has a square hole XxY = 237 x 165 mm to fit the conduits 1 x 160 mm and 1 x 75 mm
diameters or different combinations.
opening for
conduit 160 +
100
414
500
626
106
C
600
754
165
181
259
B
75
680
222
SECTION B-B
237
700
488
106
B
215
215
506
87
Indication arrow
FRONT cabinet
165
165
237
2
70
C