manualshive.com logo in svg
background image

Control Panels CP600

CP650-x, CP650-WEB-x

CP660-x, CP660-WEB-x

CP675-x, CP675-WEB-x

Operating Instructions

Содержание 1SAP550100R0001

Страница 1: ...Control Panels CP600 CP650 x CP650 WEB x CP660 x CP660 WEB x CP675 x CP675 WEB x Operating Instructions ...

Страница 2: ...chnical Specifications 7 Environmental Conditions 7 Electromagnetic Compatibility EMC 8 Durability Information 9 Technical Data 10 Dimensions 11 Installation Environment 12 Applying the Rectangular Gasket 12 Installation Procedure 13 Connections 14 Serial Ports 14 Ethernet Port 16 Power Supply Grounding and Shielding 17 AUX Port 19 Battery 20 Cleaning Faceplates 21 Getting Started 22 ...

Страница 3: ...Operating Instructions 2 CP650 CP660 CP675 System Settings 23 Dedicated LED Indicators 25 Unpacking and Packing Instructions 26 ...

Страница 4: ...hese devices into the residential commercial and light industrial environments is al lowed only in the case that special measures are taken in order to get the conformity to IEC 61000 6 3 The products are in compliance with the restrictions on Certain Hazardous Substances RoHS Directive 2002 95 EC This Operating Instruction describes the main features of the CP600 Control Panels The Operating In s...

Страница 5: ...not avoided CAUTION Indicates a possible risk It may lead to light or slight injury or material damage if not avoid ed Markups Enumeration Precondition for an operation instruction or a description Operation instruction with one step 1 Operation instruction with several steps Result of an operation NOTE Helpful information with background information or an emphasized notice TIP Application tips or...

Страница 6: ...e languages to meet global requirements Far East languages are supported Tools available in PB610 Panel Builder 600 support easy third party translations and help reducing development and maintenance costs of the application Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art HMI features Data acquisition alarm handling scheduler and timed a...

Страница 7: ...ures are taken in order to get the conformity to EN 61000 6 3 Product Identification The Control Panel products are identified by a product label The label reports several information includ ing the model name the part number the power supply the date of production in the following format ywwy and two barcodes The first code is the version code the second one the serial number S N Example of produ...

Страница 8: ...Control Panel unit s level of re sistance is equivalent to these standards oils that should have no effect on the Control Panel can possi bly harm the unit This can occur in areas where either vaporized oils are present or where low viscosity cutting oil are allowed to adhere to the unit for long periods of time If the Control Panel s front face pro tection sheet becomes peeled off these condition...

Страница 9: ...kV L1 L2 PE 1 kV L1 L2 EN 61000 4 5 Signal port Level 1 kV line to earth Immunity to conducted dis turbances inducted by radiof requency field 0 15 80 MHz 10 V EN 61000 4 6 Voltage dips short interrup tions and voltage variations immunity test Port AC mains Level 0 duration 1 cycle and 250 cycles 50 Hz or 300 cycles 60 Hz 40 duration 10 cycles 50 Hz or 12 cycles 60 Hz 70 duration 25 cycles 50 Hz o...

Страница 10: ...hout directly expose to sunlight or UV ray 10 years if the surrounding temperature is 25 C UV Resistance Indoor applications After 300 hrs cycled humidity in QUV some yellowing and brittleness may be present Touch panel resistive film analog 1 000 000 or more of activations see 2 1 Extended use in environments where the surrounding air temperature is 40 C or higher may degrade backlight quality re...

Страница 11: ...1 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 Programming printer port COM2 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 Aux port optional fieldbus Ethernet Yes Yes Yes Ethernet programming Yes Yes Yes Ethernet port 10 100 Mbit s 10 100 Mbit s 10 100 Mbit s USB port Host interface version 2 0 Host interface version 2 0 Host interface version 2 0 Graphic Yes Yes...

Страница 12: ... WEB x 326 9 30 256 10 1 42 1 65 267 10 51 337 13 26 CP675 WEB x 381 15 296 11 65 46 1 82 307 12 1 392 15 43 Model CSD Minimum compass safe distance of standard compass CSD2 Minimum compass safe distance of steering compass standby steering compass and emergency compass mm inches mm inches CP650 WEB x 400 15 74 250 9 84 CP660 WEB x 500 19 68 300 11 81 CP675 WEB x 650 25 60 400 15 74 ...

Страница 13: ...e panel or the touchscreen In order to meet the front panel protection classifications proper installation procedure must be followed The borders of the cutout must be flat The cutout for the panel must be of the dimensions indicated in this manual Screw up each fixing screw until the plastic bezel corner get in contact with the panel The IP66 is guaranteed only if Maximum deviation from the plane...

Страница 14: ...Operating Instructions 13 CP650 CP660 CP675 Installation Procedure Place the fixing brackets CAUTION Screw each fixing screw until the bezel corner gets in contact with the panel ...

Страница 15: ...type of con troller Different electrical standards are available for the signals in the PLC port connector RS 232 RS 422 RS 485 The used cable selects the appropriate signals NOTE It is always necessary to use the correct cable type to connect on the PLC If the proper cable is not used communication with the PLC will not be possible The connector is a DB 9 pin female Pin Description Pin Descriptio...

Страница 16: ...e The communication cable must be chosen for the type of device being connected Connection to an AC 500 with the TK681 CP600 AC500 RS232 communication cable Connection to an AC 500 eCo with the TK682 CP600 AC500 eCo RS485 communication cable 1 Shield 2 SubD9 male ...

Страница 17: ...5 Ethernet Port Ethernet Port A OFF No activity BLINKING Activity B ON Valid link hast NOT been detected OFF Valid link has been detected Pin Description Pin Description Pin Description Pin Description 1 TX OUT 3 RX OUT 5 7 2 TX OUT 4 6 RX OUT ...

Страница 18: ... earth connection using either the screw or the faston terminal located near the power supply terminal block A label helps identify the ground connection 2 Connect to ground the terminal 3 on the power supply terminal block 3 The power supply circuit may be floating or grounded In the latter case connect to ground the power source common as shown in the figure below with a dashed line When using t...

Страница 19: ...Operating Instructions 18 CP650 CP660 CP675 All the electronic devices in the control system must be properly grounded Grounding must be performed according to applicable regulations ...

Страница 20: ...ty of the AUX port depends on the optional Communi cation Module which is plugged into the unit NOTE The pin assignment of the AUX port connector is described in the manual of the Communi cation Module WARNING Do not plug the Communication Module and the ETAD adapter when power is applied to the operator panel 1 Open the housing 2 Insert the Communication Module pressing simultaneously on the four...

Страница 21: ...y maintains the hardware real time clock date and time Charging the Battery At first installation recharge the battery for 48 hours When the battery is charged it assures a period of 3 month of data back up at 25 C Recycling and Disposal The battery must not be disposed as unsorted domestic waste Dispose the battery according to the local regulations ...

Страница 22: ...Operating Instructions 21 CP650 CP660 CP675 Cleaning Faceplates The equipment must be cleaned only with a soft cloth and neutral soap product Do not use solvents ...

Страница 23: ...pplication and must be properly in stalled The Windows TM environment is not included in the software package PB610 Panel Builder 600 and must already be installed on the PC PB610 Panel Builder 600 uses the PC Ethernet interface to communicate with the target device Make sure that the proper firewall policy is configured in order to allow PB610 Panel Builder 600 to access the network The version o...

Страница 24: ...ime parameter that could have been changed Please contact your panel supplier for any additional information or use the System Mode activating it with the tap tap special procedure Tap tap consists in a high frequency sequence of touch activations by simple means of the finger tapping the touchscreen performed during the power up and started immediately after the panel is powered User Mode User Mo...

Страница 25: ...erating system see be low in the next chapter for additional details Download Splash Image allows changing the splash screen image displayed by the unit at power up the image should be provide in a specific format We suggest to update Splash Screen Image di rectly from Studio software which supports this feature starting from V 1 50 Download Bootloader allows to check current version of the system...

Страница 26: ...ED in the upper left part of the front below the red stripe The meaning of the LED indicator is explained in the following table LED color Status Meaning Green On Normal operation Blinking Communication error or alarm requires acknowledgement Red On Hardware fault Blinking Battery low ...

Страница 27: ...Operating Instructions 26 CP650 CP660 CP675 Unpacking and Packing Instructions To repack the unit follow the instructions backwards ...

Страница 28: ...th regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden ...

Отзывы: