Start-up test
Do a start-up test before running BullsEye.
Action
Make sure that the digital input connected to the scanning device is responding
correctly, by verifying that the signal is defined as an input on an I/O board.
1
Pass your hand through the BullsEye yoke beam to break the beam. The LED on
the I/O board corresponding to the input should turn on when the beam is broken.
If it does not, verify that the I/O board is configured properly and that the wiring is
correct.
2
26
Application manual - BullsEye
3HAC050989-001 Revision: C
© Copyright 2004-2018 ABB. All rights reserved.
3 Installation
Continued