7.2.8 Reflashing firmware failure
Description
When reflashing firmware, the automatic process can fail which will stop the system.
A message is generated in the event log.
This fault usually occurs due to a lack of compatibility between hardware and
software.
Recommended working procedure
If the controller stops with a message about firmware failure, use this procedure
to troubleshoot what might cause the problem.
Note
Action
Read the message to see which unit has failed.
1
If the relevant unit has been replaced recently,
make sure that the versions of the old and the
new unit are identical.
2
Check the software versions.
3
If RobotWare has been updated recently, make
sure that the versions of the old and the new unit
are identical.
4
If the problem remains, contact your local ABB
for information about which firmware version is
compatible with your hardware.
5
Product manual - OmniCore C90XT
381
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
7 Troubleshooting
7.2.8 Reflashing firmware failure
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21B version a6 Checked in 2021 05 31 Skribenta version 5 4 005 ...
Страница 36: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 420: ...This page is intentionally left blank ...
Страница 428: ...This page is intentionally left blank ...
Страница 452: ...This page is intentionally left blank ...
Страница 456: ......
Страница 457: ......