4.5.3 Function test of three-position enabling device
Performing the function test
Note
Action
Start the robot system and turn the mode
switch to manual mode.
1
This test is passed if the event message
10011 Motors ON state
appears in the
event log.
Press the three-position enabling device
to the middle position and then hold the
enabling device in this position.
2
If the event message
10011 Motors ON
state
does not appear, or if the event
message
20224 Enabling device conflict
appears in the event log, then the test has
failed and the root cause of the failure must
be found.
This test is passed if the event message
10012 safety guard stop state
appears in
the event log.
While still holding the three-position en-
abling device pressed, press the enabling
device harder to the enable the device's
third position.
3
If the event message
10012 Safety guard
stop state
does not appear, or if the event
message
20224 Enabling device conflict
appears in the event log, then the test has
failed and the root cause of the failure must
be found.
Product manual - OmniCore C90XT
173
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
4 Maintenance
4.5.3 Function test of three-position enabling device
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21B version a6 Checked in 2021 05 31 Skribenta version 5 4 005 ...
Страница 36: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 420: ...This page is intentionally left blank ...
Страница 428: ...This page is intentionally left blank ...
Страница 452: ...This page is intentionally left blank ...
Страница 456: ......
Страница 457: ......