4.6.5 Restoring the balancing device
Overview
This section details how to restore the balancing device and how to remove the
press tool from the device.
DANGER
There is a high tensioned spring inside the balancing device, incorrect handling
may cause injuries and damage property.
Press tool and hydraulic cylinder
The figure below shows the hydraulic cylinder mounted on the press tool.
The press tool includes two press devices that are used to different models of the
balancing device.
xx0200000174
Press block
A
Hydraulic cylinder
B
Press device
C
Bolt, press device
D
Moving pin with marking
E
Continues on next page
Product manual - IRB 6790
415
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.