Publication No. PPC11A-HRM/1
About This Manual 5
Component
Information
QorIQ T1042, T1022 Data Sheet, NXP
T1040 QorIQ Advanced Multiprocessing Processor Reference Manual, NXP
QorIQ T2080 Reference Manual, NXP
T2081 QorIQ Integrated Multicore Communications Processor Reference Manual,
NXP
Universe IID User Manual, IDT
PCI Total-ACE Data Sheet, DDC
XR17V358 High Performance Octal PCIe UART, EXAR
PEX8619 BA Data Book, Broadcom (PLX)
MachXO2 FPGA Datasheet, Lattice
Safety Notices
Cooling
CAUTION
The PPC11A requires air-flow of at least 300 lfm for build levels 1 and 2, and at least 600 lfm for build
level 3. If a conduction-cooled (level 4 or 5) PPC11A is operating on an extender card, it requires air-flow of
at least 300 lfm across it.
Handling
CAUTION
Only handle the PPC11A by the edges or front panel
ESD Label (Present on Board Packaging)
Heatsink
CAUTIONS
Do not remove the heatsink. There are no user-alterable components underneath the heatsink, so users
should have no reason to remove it.
Users should not attempt reattachment of the heatsink, as this requires precise torque on the screws
attaching the heatsink to the PCB. Over-tightening the screws may cause the heatsink to damage
components beneath it. Removal and re-attachment of the heatsink should only be carried out by Abaco.