Содержание PMC423

Страница 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective o...

Страница 2: ...O THE PMC423 IS DESIGNED TO MEET THE EUROPEAN UNION EU RESTRICTIONS OF HAZARDOUS SUBSTANCE ROHS DIRECTIVE 2002 95 EC CURRENT REVISION Publication No RX URMH 006 Rev E 0 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...Returns Abaco Systems is registered with an approved Producer Compliance Scheme PCS and subject to suitable contractual arrangements being in place will ensure WEEE is processed in accordance with the requirements of the WEEE Directive Abaco Systems will evaluate requests to take back products purchased by our customers before August 13 2005 on a case by case basis A WEEE management fee may apply ...

Страница 4: ...The prefix 0x shows a hexadecimal number following the C programming language convention Thus One dozen 12D 0x0C 1100b The multipliers k M and G have their conventional scientific and engineering meanings of x103 x106 and x109 respectively and can be used to define a transfer rate The only exception to this is in the description of the size of memory areas when K M and G mean x210 x220 and x230 re...

Страница 5: ...ance contact details on the Embedded Support page LINK https www abaco com embedded support Abaco will log your query in the Technical Support database and allocate it a unique Case number for use in any future correspondence Alternatively you may also contact Abaco s Technical Support at the website below LINK support abaco com Returns If you need to return a product there is a Return Materials A...

Страница 6: ...Features The PMC423 is a powerful and flexible method to integrate serial data channels to a PCI system Features include Sixteen independent serial channels Programmable baud rate from 100 bits second to 921 6Kbits s with default Crystal at 14 7456 MHz UART register sets compatible with 16C550 64 Byte First in First out FIFO per channel Full PCI compatibility 32 bit 33 and 66 MHz PCI capable Signa...

Страница 7: ...ve Atmosphere Do not operate the system in the presence of flammable gases or fumes Operation of any electrical system in such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operating personnel must not remove product covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with power cable con...

Страница 8: ...utions 10 1 2 Unpacking Procedures 10 1 3 Installation 11 1 4 Front Panel Connectors and Indicators 12 1 5 I O Signal Pinouts 14 1 5 1 RS485 Support SW2 SW12 16 2 Theory of Operation 18 2 1 PMC423 Block Diagram 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 9: ...r I O Publication No RX URMH 006 Rev E 0 List of Tables Table 1 1 I O Signal Pinouts PMC423 14 Table 1 2 RS485 Support Switches SW2 SW12 16 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...ure 1 1 Installation of PMC Module 11 Figure 1 2 Front Panel Connectors and Indicator 12 Figure 1 3 PIM422 13 Figure 1 4 Default Switch Settings 17 Figure 2 1 PMC423 Block Diagram 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 11: ...iguring etc it is suggested that conductive material be inserted under the board to provide a conductive shunt Unused boards should be stored in the same protective boxes in which they were shipped 1 2 Unpacking Procedures Any precautions found in the shipping container should be observed All items should be carefully unpacked and thoroughly inspected for damage that might have occurred during shi...

Страница 12: ...g connectors on the host s printed circuit board 5 Make sure the PMC module is seated properly into the common mezzanine card CMC connectors on the host 6 Use screws to fasten PMC to the host CMC 7 Remove the four screws from the bottom of the stand offs of the PMC 8 Lineup the J1 and J2 connectors on the host CMC to the J1 and J2 connectors on the PMC 9 Ensure all connectors are properly aligned ...

Страница 13: ...onnectors and Indicators The front panel connector is a high density small computer system interface SCSI female connector AMP part number AMP 796055 1 Figure 1 2 Front Panel Connectors and Indicator Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 14: ...Publication No RX URMH 006 Rev E 0 Handling and Installation 13 Figure 1 3 PIM422 TOP BOTTOM Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 15: ...lane connector The following table details all connections Table 1 1 I O Signal Pinouts PMC423 Port Signal Front Panel Pin J4 Pin Positive Negative Positive Negative 1 RX 2 1 2 1 TX 4 3 4 3 2 RX 6 5 6 5 TX 8 7 8 7 3 RX 11 10 10 9 TX 13 12 12 11 4 RX 15 14 14 13 TX 17 16 16 15 5 RX 19 18 18 17 TX 21 20 20 19 6 RX 23 22 22 21 TX 25 24 24 23 7 RX 28 26 26 25 TX 30 29 28 27 8 RX 32 31 30 29 TX 34 33 3...

Страница 16: ...Positive Negative 13 RX 53 52 50 49 TX 55 54 52 51 14 RX 57 56 54 53 TX 59 58 56 55 15 RX 62 60 58 57 TX 64 63 60 59 16 RX 66 65 62 61 TX 68 67 64 63 NOTE Ground is available on the front panel connector on pins 9 27 43 and 61 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 17: ...ls As shipped from factory all switches are in the Open state Table 1 2 RS485 Support Switches SW2 SW12 Port 1 SW1 1 SW2 1 SW9 1 2 SW1 2 SW2 2 SW9 2 3 SW1 3 SW2 3 SW9 3 4 SW1 4 SW2 4 SW9 4 5 SW3 1 SW4 1 SW10 1 6 SW3 2 SW4 2 SW10 2 7 SW3 3 SW4 3 SW10 3 8 SW3 4 SW4 4 SW10 4 9 SW5 1 SW6 1 SW11 1 10 SW5 2 SW6 2 SW11 2 11 SW5 3 SW6 3 SW11 3 12 SW5 4 SW6 4 SW11 4 13 SW7 1 SW8 1 SW12 1 14 SW7 2 SW8 2 SW1...

Страница 18: ...Publication No RX URMH 006 Rev E 0 Handling and Installation 17 Figure 1 4 Default Switch Settings Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 19: ...or the serial communication RS232 RS422 etc is configured via the software The card generates the necessary voltage for the serial signaling onboard using the 5 V supply This allows the PMC423 to operate from the 3 3 V and 5 V supply only There are two eight port serial devices that are after the PCI to PCI bridge for a total of sixteen ports Due to the density of the serial ports the hardware han...

Страница 20: ...cter transferred and control operations The Octal UART utilized on the PMC423 supports 32 bit transfers allowing four characters to be transferred in a single bus operation Reducing programmed I O operations is critical to achieving good performance in PCI systems While the extended transfer options offer an opportunity to maximize performance in many cases the first and sometimes only criteria ar...

Страница 21: ...ITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE ON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED Abaco Systems Information Centers Americas 1 866 652 2226 866 OK ABACO Europe Middle East and Africa 44 0 1327 359444 Ad...

Страница 22: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: