5011679300-T3M0
Service Bulletin
PowerFlex 400 Frames D-H
Replacement Procedure for Main Control Board
Contents
This publication provides instructions for replacing the main control board
for PowerFlex 400 Frames D through H drives. For additional drive
information, refer to the PowerFlex 400 User Manual, publication
22C-UM001....
What This Kit Contains
•
Main control board assembly consisting of a main control board, an LCD
Human Interface Module (HIM), and a plastic tray
•
Four spare tapping
φ
4*8 mm screws (for Frame D) and
four spare M4*8 mm screws (for Frames E-H)
to be used for the plastic tray
•
This publication
Safety Precautions
The following general precautions apply to the PowerFlex 400 drive.
!
ATTENTION: To avoid an electric shock hazard, verify that the
voltage on the bus capacitors has discharged before performing
any work on the drive. Wait five minutes for the capacitors to
discharge. Then, measure the DC bus voltage at the DC- and
DC+ terminals or at the DC- and P2 terminals on the power
terminal block. The voltage must be zero.
A darkened LCD display and LEDs are not an indication that
capacitors have discharged to safe voltage levels.
!
Only qualified electrical personnel familiar with the construction
and operation of this equipment and hazards involved should
install, start and/or adjust this equipment. Read and understand
these instructions in their entirety before proceeding. Failure to
observe this precaution could result in severe bodily injury or
loss of life.
!
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.