Publication 1394-5.0 — May 2000
8-18
Configuring Your 1394 Analog Servo System
[Option x Code]
Used for software options
Option 0 = Antibacklash
Option 1 = Future
Option 2 = Future
Option 3 = Future
Parameter Numbers
30, 32, 34, 36
Parameter Group
Linear List
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
0
Maximum Value
65535
Default Value
0
[Option x Status]
Present status of a software option (enabled/
disabled). Once enabled via the [Option x Code]
the status will be stored in non-volatile memory
for future use.
Parameter Numbers
31, 33, 35, 37
Parameter Group
Linear List
Display Units
None
Parameter Type
Read Only
Linkable
No
Selections
0
"Disabled"
1
"Enabled"
[Pos Cur Lim]
Specifies the maximum allowable positive motor
current that can be commanded.
Important: Setting this parameter to a value
other than default will limit motor output torque
in CW direction. Automatically changed when
[Current Limit] (parameter 116) is changed.
For Example: If the value equals 100%, the Axis
Module will not deliver more than 100% to motor,
thus peak torque is limited to 100%.
Parameter Numbers
184, 185, 186, 187
Parameter Group
Torq Data
Display Units
amps
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
10% rated motor current
Maximum Value
300% rated motor current or 2 times drive rating
(whichever is less)
Default Value
300% rated motor current
[Prop Gain Kp]
This parameter controls the proportional error
gain of the velocity regulator. For example, if
KP = 1, then velocity error of 1000 rpm will
produce a (rated motor) current torque
reference.
Increase this value to attain a stiffer, more
precise response.
Parameter Numbers
368, 369, 370, 371
Parameter Group
Vel Loop Tune, AnBklsh Conf
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
0
Maximum Value
1024
Default Value
0
[Pwr On Days]
Displays the number of days that the drive has
had control power applied.
Parameter Numbers
91
Parameter Group
Linear List
Display Units
None
Parameter Type
Read Only
Linkable
No
[Pwr On Minutes]
Displays the number of minutes that the drive has
presently had control power applied.
Parameter Numbers
90
Parameter Group
Linear List
Display Units
None
Parameter Type
Read Only
Linkable
No
[Rem. Data In/Out:Ax]
This series of parameters represent linkable
inputs and outputs to the SCANport Type 4/5/6/
7 DataLink inputs and outputs.
Parameter Numbers
70-85
Parameter Group
Linear List
Display Units
None
Parameter Type
Read Only
Linkable
In=No, Out=Yes
Содержание Allen-Bradley 1394
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...