Publication 1394-5.0 — May 2000
8-10
Configuring Your 1394 Analog Servo System
[Disp-D/A Monitor]
This parameter quickly establishes links to the
D/A test points. It will link the selected axis [Iq
Cur Ref] to test point 1, and the [Vel Feedback]
to test point 2. It will also link the [Vel Feedback]
to all the SCANport analog display parameters.
Parameter Numbers
20
Parameter Group
Setup
Display Units
None
Parameter Type
Read/Write
Change While Running
No
Linkable
No
Default Value
0
"Axis 0"
Selections
0
"Axis 0"
1
"Axis 1"
2
"Axis 2"
3
"Axis 3"
4
"Not Linked"
[Drive OK Mode]
This parameter selects operation of the Drive OK
relay. (DROK)
Parameter Numbers
19
Parameter Group
Setup
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
"Fault Only"
Selections
0
"Fault Only"active fault opens DROK relay.
1
"Fault and UVlt"active fault or bus undervoltage opens DROK
relay.
Содержание Allen-Bradley 1394
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...