Installation Instructions

Compact 16-point 24V dc Sink/Source High-speed 
Input Module

Catalog Number 1769-IQ16F

Use this document as a guide when installing a Compact™ 16-point 24V dc sink/source 
high-speed input module.

 

Topic

Page

Important User Information

2

Module Description

3

Module Installation

4

Mounting Expansion I/O

6

Replacing a Single Module within a System

8

Field Wiring Connections

9

Spare/Replacement Module Parts

12

Specifications

13

Hazardous Location Considerations

15

For More Information

16

Содержание 1769-IQ16F

Страница 1: ... guide when installing a Compact 16 point 24V dc sink source high speed input module Topic Page Important User Information 2 Module Description 3 Module Installation 4 Mounting Expansion I O 6 Replacing a Single Module within a System 8 Field Wiring Connections 9 Spare Replacement Module Parts 12 Specifications 13 Hazardous Location Considerations 15 For More Information 16 ...

Страница 2: ...Allen Bradley publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation office describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication Reproduction of the...

Страница 3: ...ate label 7a upper tongue and groove slots 7b lower tongue and groove slots 8a upper DIN rail latch 8b lower DIN rail latch 9 write on label user ID tag 10 removable terminal block RTB with finger safe cover 10a RTB upper retaining screw 10b RTB lower retaining screw 10a 10b 4 10 2b 3 2a 1 5a 9 5b 6 7a 7b 8b 7b 8a 7a 1769 IQ16 DANGER Do Not Remove RTB Under Power Unless Area is Non Hazardous Ensur...

Страница 4: ...gree 2 and Over Voltage Category II are International Electrotechnical Commission IEC designations ATTENTION Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins Follow these guidelines when you handle the module Touch a grounded object to discharge static potential Wear an approved wrist strap grounding device Do not touch the bus connector or c...

Страница 5: ... bus lever of the module to be installed is in the unlocked fully right position 3 Use the upper and lower tongue and groove slots 1 to secure the modules together or to a controller 4 Move the module back along the tongue and groove slots until the bus connectors 2 line up with each other 5 Push the bus lever back slightly to clear the positioning tab 3 Use your fingers or a small screw driver 6 ...

Страница 6: ...dequate ventilation as shown Panel Mounting Mount the module to a panel using two screws per module Use M4 or 8 panhead screws Mounting screws are required on every module IMPORTANT A 1769 ECR or 1769 ECL right or left end cap must be used to terminate the end of the serial communication bus ATTENTION During panel or DIN rail mounting of all devices be sure that all debris metal chips wire strands...

Страница 7: ...nting holes on the panel 3 Return the assembled modules to the clean work surface including any previously mounted modules 4 Drill and tap the mounting holes for the recommended M4 or 8 screw 5 Place the modules back on the panel and check for proper hole alignment 6 Attach the modules to the panel using the mounting screws 7 Repeat steps 1 to 6 for any remaining modules TIP If mounting more modul...

Страница 8: ... the bus lever to the right to disconnect unlock the bus 4 On the right side adjacent module move its bus lever to the right unlock to disconnect it from the module to be removed 5 Gently slide the disconnected module forward If you feel excessive resistance check that the module has been disconnected from the bus and that both mounting screws have been removed or DIN latches opened 6 Before insta...

Страница 9: ...eld device Sourcing I O circuits supply source current to sinking field devices Sinking I O circuits are driven by a current sourcing field device Field devices connected to the negative side DC Common of the field power supply are sinking field devices Field devices connected to the positive side V of the field supply are sourcing field devices Europe DC sinking input and sourcing output module c...

Страница 10: ... screws The terminal block will back away from the module as you remove the screws When replacing the terminal block torque the retaining screws to 0 46 Nm 4 1 in lbs Wiring the Finger Safe Terminal Block When wiring the terminal block keep the finger safe cover in place 1 Loosen the terminal screws to be wired 2 Route the wire under the terminal pressure plate You can use the bare wire or a spade...

Страница 11: ... contains the current state of the field input points r read TIP If you need to remove the finger safe cover insert a screw driver into one of the square wiring holes and gently pry the cover off If you wire the terminal block with the finger safe cover removed you will not be able to put it back on the terminal block because the wires will be in the way Wire Type Wire Size Terminal Screw Torque R...

Страница 12: ...er some systems e g 1769 ADN DeviceNet Adapter also allow the bits to be altered as part of the control program using communication rungs In that case it is necessary to understand the bit arrangement Spare Replacement Module Parts Terminal Block 1769 RTBN18 1 per kit Door Label 1769 RL1 2 per kit Door 1769 RD 2 per kit Word Bit Position 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 Filter Time On to Of...

Страница 13: ...ounted Relay Operation 7 5G panel mounted 5G DIN rail mounted Non Operating 40G panel mounted 30G DIN rail mounted Agency Certification C UL certified under CSA C22 2 No 142 UL 508 listed CE compliant for all applicable directives Hazardous Environment Class Class I Division 2 Hazardous Location Groups A B C D UL 1604 C UL under CSA C22 2 No 213 Radiated and Conducted Emissions EN50081 2 Class A E...

Страница 14: ...tts The Watts per point plus the minimum Watts with all points energized Digital Filter OFF to ON 0s 100µs 500µs 1ms 2ms ON to OFF 0s 100µs 500µs 1ms 2ms Hardware Delay OFF to ON 100µs typical 300µs maximum ON to OFF 250µs typical 1ms maximum Off State Voltage max 5V dc Off State Current max 1 5 mA On State Voltage min 10V dc On State Current min 2 0 mA Inrush Current max 250 mA Nominal Impedance ...

Страница 15: ...sion 2 Do not replace components or disconnect equipment unless power has been switched off or the area is known to be non hazardous Do not connect or disconnect components unless power has been switched off or the area is known to be non hazardous This product must be installed in an enclosure All wiring must comply with N E C article 501 4 b ATTENTION DANGER D EXPLOSION La substitution de compos...

Страница 16: ...ada Compact and MicroLogix are trademarks of Rockwell Automation For Refer to this Document Pub No a more detailed description of how to install and use your Compact I O with MicroLogix 1200 1500 programmable controller MicroLogix 1200 and MicroLogix 1500 Programmable Controllers User Manual 1764 RM001B US P a more detailed description of how to install and use your Compact I O with the 1769 ADN D...