Page 6-111
10/2008
AMT/PTD/TR/0020/2/7/EN
6.2.6 LDS card layout
The LDS card can be fitted in the shelves in accordance with the configuration file. The card is
connected to the synchronous bus via the AVADQ or AVLDT terminator inserted in a CFX front
slot (corresponding to CLX slot on the LDS card).
For more details, refer to "Reference documents" on page 13.
The LDS card must be connected to a synchronising clock input in the PBX if a T0 interface is
synchronising on the LDS card.
Each group of eight S interfaces must be connected to a complete junction (32 TS) on the
synchronous bus of the NeXspan 50. The LDSA card thus requires two junctions.
To synchronise the NeXspan 50, connect the ISDN clock extracted from a T0 access
(synchronising T0 interface) to a 2.048 MHz clock input of the RSU.
Cards
CLX0
CLX1
CLX2
CLX3
CLX4
CLX5
CLX6
Trunks
J8 + J12
J9 + J13
J10 + J14
J24 + J28
J25 + J29
J26 + J30
J27 + J31
Capacity
8S (J8)
16S (J8, J12)
8S (J9)
16S (J9, J13)
8S (J10)
16S (J10,
J14)
8 S (J24)
16 S (J24, J28)
8 S (J25)
16 S (J25, J29)
8 S (J26)
16 S (J26, J30)
8 S (J27)
16 S (J27,
J31)
Содержание X Series
Страница 3: ......
Страница 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Страница 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Страница 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 209: ...Page 12 209 10 2008 AMT PTD TR 0020 2 7 EN...