Mounting the OpenCom 150 Rack InfoCom System
Safety Precautions
72
6.
Mounting the OpenCom 150 Rack
InfoCom System
The OpenCom 150 is also available as rack version for mounting in a standard
19" EIA rackmount cabinet.
OpenCom 150 Rack Frame and Ports
6.1
Safety Precautions
The system needs to be mounted in earthed cabinets or cases. Lines and cables
connected to the communications system must only be laid inside buildings.
Use a shielded Ethernet cable (STP cable, Shielded Twisted Pair cable) to connect
the OpenCom 150 to a Local Area Network (LAN).
The ambient temperature of the OpenCom 150 Rack infocom system should not
exceed 55°C. If the device is installed together with other active components, it
may be necessary to mount additional ventilation fans in the installation cabinet.
Patch cables have to be connected before connecting the system to the power
supply. Installation of the system, and in particular connection to the power
supply and protective earthing, should only be performed by skilled, qualified per-
sonnel. EN, IEC regulations, along with other recognised technical rules regarding
safety, must be observed.
Please note:
Before opening the device, pull out the plug.
DSL
Содержание OpenCom 100
Страница 1: ...130 OpenCom100 131 150 Mounting and Commissioning User Guide...
Страница 10: ...8...
Страница 240: ...Index 238 X XML 124...
Страница 241: ...Index 239 Notes...
Страница 242: ...Index 240 Notes...
Страница 243: ......
Страница 244: ...www aastra com As of 19 07 2009 Subject to changes...