7. 4
Technical Data
7. 4. 1
Basic Systems
Tab. 107 Dimensions and weights
Tab. 108 Electrical isolation of interfaces
Tab. 109 Ambient conditions
Tab. 110 Electrical data
Tab. 111 Heat dissipation
A150/300, wall-mounted
A150/300, rack-mounted
Height
65 mm
65 mm
Width
360 mm
483 mm
Depth
294mm
294mm
Weight (excl. mains cord, expansion
cards and packaging)
2.4 kg
2.5 kg
Interface
all systems
Analogue network interfaces
0.2 kV
Operating isolation
Digital network interfaces BA
65 V
Operating isolation
V.24 on the Pocket Adapter
0.5 kV
Control input on ODAB
no isolation, but input impedance > 8 k
Ω
Freely connectable relay on ODAB
0.2 kV
Door intercom system on ODAB
0.2 kV
Audio input
no isolation
Condition
all systems
Ambient temperature
5 °C to 35 °C
Relative air humidity
30% to 80%, non-condensating
A150
A300
Class of protection
1
Input voltage
95 V…253 V, 48…62 Hz
Input current
approx. 0.11 A...0.7 A.
approx. 0.11 A...1.0 A
Resistant to voltage breaks
< 6 ms
Power input with min. configuration
ca. 15 W
ca. 15 W
Power input with max. configuration
ca. 50 W
ca. 75 W
Undervoltage limit (system reset, data backup)
< 90 V
A150
A300
Maximally configured system
approx. 37 W = 135 kJ/h
approx. 50 W = 180 kJ/h