6. 6
Operations supervision
6. 6. 1
Event message concept
The PBX generates an event message every time an event or error occurs. The
event tables in the Fault & Maintenance Manager are used to specify how often an
event message of a particular type may be generated over a given time period be-
fore the event message is sent to the allocated signal destinations.
The Fault & Maintenance Manager has 4 event tables that can be allocated to 4 sig-
nal destinations:
F = Frequency
T = Time period
Fig. 76
Distribution principle for an event message
1
Event
tables
Signal
destinations
Terminal
External signal
destination
Local signal
destination
• PC with SEM on
TA / ISDN Gateway
• System
terminal
with display in
message
group
• Printer / PC with