Ascotel® IntelliGate® 150/300 as of I7.9
186
Operation and Maintenance
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
Carrying out a first start
The following sequence carries out a system first start.
Note:
A system first start deletes all the configuration data, which is reset to its
initialization values. Save the data beforehand with a backup. The data
stored on the EIM card is not deleted by a first start of the PBX, and
remains available.
Requirement: The system is in the Boot Command Mode (pattern 18).
1.
Press the pilot key briefly.
→
"F1" lights up red
2.
Press the pilot key with a long keypress (LC).
→
After 2 second keypress "F1" lights up green by way of confirmation.
→
The first start is initiated once the key is released.
→
The system now deletes the database. The process can last up to 30 seconds
and is displayed with pattern 19. The startup then continues normally.
Tab. 91
Patterns while the database is deleted as a result of a first start
See also:
"Carrying out functions", page 180
Resetting the IP address
The IP address data is stored on the EIM card and is retained even after a first start.
The following sequence only resets the IP address data of the basic system to the
initialization values. All the other data is retained.
Requirement: The system is in the Boot Command Mode (pattern 18).
1.
Press the pilot key several times with a short keypress (SC) until "F2" lights up
red.
2.
Press the pilot key with a long keypress (LC)
→
After 2 second keypress "F2" lights up green by way of confirmation.
→
The IP address data is reset to the initialization values once the key is released.
The startup then continues normally.
Pattern
No.
F0
F1
F2
F3
F4
SYS
Dura-
tion [s]
Meaning
19
~30
Deleting the database
' n
' n
' n
n
n
n