Ascotel® IntelliGate® 150/300 as of I7.9
172
Operation and Maintenance
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
The system configuration data (User No., User configuration, etc.) of the terminals
on the new ports is created as new data (initialization values).
Tab. 79
Example: Expanding the number of terminal or network interfaces
6. 3. 3. 4
Change slot
Interface cards can be moved to a different slot. The terminal configuration data of
the system terminals can be transferred.
Procedure:
1.
Change the slot and put the PBX into operation again. Similar procedure as de-
scribed in
"Replacing a defective interface card", page 170
Note:
The wiring adapter must also be changed to the corresponding slot.
Any incorrectly fitted or missing wiring adapters are signalled by a red
flashing LED on the display after start-up (see
).
2.
Connect the system terminals to the ports of the new slot.
3.
Re-configure port allocation using the AIMS Configuration Manager.
4.
Insert the card in the new slot in AIMS and remove it from the old slot. The con-
figuration data at the old slot location is now deleted.
Note:
Not all cards can be equipped on all slots (see
).
SC-08AD2
→
SC-16AD2
The configuration data of terminal interfaces 9...16 is created as new data.
ISDN-04ST
→
SC-08AD2
The configuration data of all 8 terminal interfaces is created as new data.