A-254
41-001343-01 Rev 02, Release 3.2.2
WatchDog Settings
Examples
Enter a debug level value in the “
Debug Level
” field for a module.
Example 1
To turn two or more debug levels on at the same time, you add the value
associated with each level. For example,
Fatal Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are
logged for the line manager, user interface, and SIP call control modules.
Example 2
Functions and Info = 16 + 32 = 48
log module dis: 48
log module net: 48
log module snd: 48
In the above example, functions and general information are logged for
the display drivers, network, and sound modules.
Example 3
log module rtpt: 0
log module ind: 65535
In the above example, all debug levels are OFF for the Real Time
Transport module. All debug levels are ON for the indicator module.
You can set the Module/Debug Levels using the configuration files or the
Aastra Web UI.
Parameter
–
watchdog enable
WatchDog
(in Web UI)
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Aastra Web UI
Advanced Settings->Troubleshooting
Description
Enables/disables the use of the WatchDog task for the IP Phones.
Format
Boolean
Default Value
1 (enabled)
Range
0 (disabled)
1 (enabled)
Example
watchdog enable: 0
Содержание 6700i Series
Страница 3: ......
Страница 17: ......
Страница 67: ......
Страница 163: ......
Страница 275: ...4 112 41 001343 01 Rev 02 Release 3 2 2 Aastra Web UI Step Action 1 Click on Advanced Settings Configuration Server ...
Страница 334: ...41 001343 01 Rev 02 Release 3 2 2 5 57 ...
Страница 681: ......
Страница 687: ......
Страница 981: ......
Страница 985: ......
Страница 1016: ...41 001343 01 Rev 02 Release 3 2 2 C 31 prgkey5 line 1 list prgkey6 type list prgkey7 type list ...
Страница 1017: ......
Страница 1021: ......
Страница 1025: ......
Страница 1037: ......