manualshive.com logo in svg
background image

 

 

 

Wrist Digital Blood Pressure Monitor 

Model  UB

-

533

 

Instruction Manual 

Original 

Manuel d’instructions 

Traduction 

Manual de Instrucciones 

Traducción 

Manuale di Istruzioni 

Traduzione 

使用手冊

 

1WMPD4003121 

翻譯

 

Содержание UB-533

Страница 1: ...Wrist Digital Blood Pressure Monitor Model UB 533 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducci n Manuale di Istruzioni Traduzione 1WMPD4003121...

Страница 2: ...cting the C P G and my C P G 11 8 Measurement 12 9 After Measurement 12 Measurements 13 Recalling the Memory Data 14 Deleting Data Stored in Memory 15 What is an Irregular Heartbeat 15 IHB 16 Pressure...

Страница 3: ...pressure and pulse rate of people for diagnosis Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be a...

Страница 4: ...using the device Do not let children use the device by themselves and do not use the device in a place within the reach of infants There are small parts that may cause a choking hazard if swallowed b...

Страница 5: ...e clock display AM PM mark Alkaline batteries LR03 or AAA Battery cover button average memory and change of preset parameters SET button user selection and clock START button Carrying case Display Hea...

Страница 6: ...ry installation guide Direct current SN Serial number Date of manufacture Type BF Device and cuff are designed to provide special protection against electrical shocks EC directive medical device label...

Страница 7: ...d It may light when a very slight vibration like shivering or shaking is detected Appears when a body or arm movement is detected The reading may yield an incorrect value Take another measurement Rema...

Страница 8: ...ll during measurement The systolic and diastolic values are within 10 mmHg of each other Apply the cuff correctly and take another measurement The pressure value did not increase during inflation The...

Страница 9: ...s with new ones Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained The battery life var...

Страница 10: ...th day selection The date can be set anywhere between the years 2010 and 2059 3 Select the month using the button Press the SET button to set the current month and move to day selection 4 Select the d...

Страница 11: ...e faster than normal Try to measure your blood pressure at about the same time every day An individual s blood pressure varies constantly depending on what they are doing what they have eaten and what...

Страница 12: ...n off Proceed to 8 Measurement If you use my C P G function proceed to 7 Selecting the C P G and my C P G 7 Selecting the C P G and my C P G You can select an indicator either the C P G function or my...

Страница 13: ...if you press the START button to turn the device off new readings are stored in memory While readings are displayed if you press the button to turn the device off new readings are not stored Remove th...

Страница 14: ...ation starts and the heart mark blinks Note If you wish to stop inflation at any time press the START button again 5 When the measurement is complete the device displays readings of the systolic and d...

Страница 15: ...data of all PM evening measurements taken between 18 00 and 1 59 Data of number and measurement data The device displays in order from most recent data The date and time are displayed alternately whi...

Страница 16: ...while blinking the mark and turns off automatically Note This operation will delete specified user data stored in memory You cannot select which data to delete What is an Irregular Heartbeat The UB 5...

Страница 17: ...refore we recommend contacting your physician if IHB level is high Number of detected IHBs in memory Display of IHB IHB is displayed when displaying average values IHB is not displayed when the memory...

Страница 18: ...essure classification is described on 20 page Example Moderate hypertension Mild hypertension High normal Pressurizing Inflation in progress Measurement in progress Inflation complete The indicator di...

Страница 19: ...than your heart High angle Incorrect Height The position of the device is checked both before and after measurement If both checks show a correct measurement position the LEVEL indicator is lit blue F...

Страница 20: ...ore eating What is Hypertension and How is it Controlled Hypertension an abnormally high arterial blood pressure if left unattended can cause many health problems including stroke and heart attack Hyp...

Страница 21: ...this manual to get to know your normal blood pressure Regular readings give a more comprehensive blood pressure history Be sure to note the date and time when recording your blood pressure Consult you...

Страница 22: ...d properly Apply the cuff correctly You moved your wrist or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortabl...

Страница 23: ...e 13 5 21 5 cm Classification Internally powered ME equipment Continuous operation mode Applied part Cuff Type BF Useful life Device 5 years when used six times a day Clinical test According to ANSI A...

Страница 24: ...on Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 26...

Отзывы: