Страница 1: ...A D Medical DELUXE BLOOD PRESSURE MONITOR UA 651 AC Series LJA 651S AC UA 651M AC UA 651L AC UA 651 W A C Rc ic q Instruction Manual ORIGINAL English 1WMPD4003536 ...

Страница 2: ...i Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulations U When the AC adapter is used make sure that the AC adapter can be readily removed from the electrical outlet when necessary U Do not modify the device It may cause accidents or damage to the device U To measure blood pressure the arm must be squeez...

Страница 3: ...use accidents or damage U There are small parts that may cause a choking hazard if swallowed by mistake by infants U Use of accessories not detailed in this manual may compromise safety U Unplug the AC adapter when not in use during the measurement U Should the battery short circuit it may become hot and potentially cause burns U Clinical testing has not been conducted on newborn infants and pregn...

Страница 4: ... an irregular heartbeat is detected It may light when a very slight vibration like shivering or shaking is detected M Previous measurements stored in memory FULL BATTERY The battery power indicator during measurement rfj LOW BATTERY The battery power is tow when it blinks Replace all batteries with new OfleS when the indicator blinks 11 A Err Unstable blood pressure due to movement during the meas...

Страница 5: ...mbol SN Serial number Refer to instruction manual booklet Polarity of DC jack Clock setting Clock adjustment and memory recall Keep dry Installing Batteries 1 Remove the battery cover 2 Remove the used batteries from the battery compartment in case of changing them 3 Insert new batteries into the battery compartment as shown taking care that he polarities and are correct 4 Replace the battery cove...

Страница 6: ...TTERY mark blinks on the display replace all batteries with new ones Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction U Replace the batteries two seconds or more after thedevice turns off U If C LOW BATTERY mark appears even after the batteries are replaced make a blood pressure measurement The device may then recognize the new batteries U E LOW B...

Страница 7: ...on Pressurizing Measurement in progress Systolic Pressure Diastolic Pressure JNC7 classification Pulse Rate Exhausts remaining air automatically j Turnoff with the start button IBB IBBB tag U U U ISO I 9U Using the monitor Measurements Model UA 651 AC is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically Normal Measurement 1 Place the cuff on the arm pr...

Страница 8: ... on a chair Rest your arm on the table Do not cross your legs Keep your feet on the floor and straighten your back U Relax for about five to ten minutes before taking a measurement LI If you are excited or depressed by emotional stress the measurement will reflect this Stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal U An indiv...

Страница 9: ...ased When the set date and time is erased please adjust again What is an Irregular Heartbeat The UA 651 AC blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs An irregular heartbeat is defined as a heartbeat that varies by 25 from the average of all heartbeats during the blood pressure measurement It is important that you are relaxed ...

Страница 10: ...riations are even more pronounced Normally blood pressure rises during work or play and falls to its lowest levels during sleep About Blood Pressure What is Hypertension and How is it Controlled Hypertension an abnormally high arterial blood pressure if left unattended can cause many health problems including stroke and heart attack Hypertension can be controlled by altering lifestyle avoiding str...

Страница 11: ...s are drained Replace all batteries with the new ones Battery terminals are not in the correct position Reinstall the batteries with negative and positive terminals matching those indicated on the battery compartment The cuff does not inflate Battery voltage is too low LOW BATTERY mark blinks If the batteries are drained completely the mark does not appear Replace all batteries with new ones The d...

Страница 12: ...asurements Classification EMC Memory Operating conditions Pressure 0 209 mmHg Systolic pressure 60 279 mmHg Diastolic pressure 40 200 mmHg Pulse 40 180 beats minute Pressure 3 mmHg Pulse 5 4 x 1 5V batteries R6P LR6 AA or AC Adapter TB 233 Approx 700 times LR6 alkaline baiter es Approx 200 times R61P With pressure value 180 mmHg room temperature 23 C Internally powered ME equipment Supplied by bat...

Страница 13: ...the Product is defective then You return the Product to A D in accordance with the procedure set forth below A D s warranty obligation is limited to the repair or replacement at A D s Option of the defective Product that has been returned by You within the warranty period Such repair or replacement will be at no charge to You The repaired or replacement Product is warranted here under for the long...

Страница 14: ...terials to A D The above remedy of repair replacement or refund is your Only and exclusive remedy IN NO EVENT SHALL A D BE LIABLE FOR ANY DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS LOST INFORMATION OR REPLACEMENT COSTS ARISING OUT OF YOUR USE OF OR INABILITY TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF A D HAS BEEN ADVISED OF THE PO...

Страница 15: ...cado por A D Company Limited 1 243 Asahi Kitamoto shi Saitama 364 8585 Japan wwwaandd jp 81 48 93 1119 Manufactured fort Fabncado para A D Engineering Inc 1756 Automation Parkway San Jose CA 95131 USA www andmedical com 1 888 726 9966 ...