Applicable models
■
Functions available for each model, accessories needed for connection to AD8551R.
Accessories needed to connect the AD8551R
to a weighing device
Modbus RTU
Command
mode
⋆1
Convenient functions
Weighing device
output options
Cable needed for
connection between
weighing device and
AD8551R
Data that can be read from the host
Operations that can be made from the host
Power supply
from the
weighing
device
Auto power on
function
⋆2
Weighing
value
Status
information
Response
speed
Calibration status
Calibration weight
value
Re-zero
Zero
Taring
Calibration with
internal weight
Calibration with your
own weight
Changing
the
display
digit
Changing the
response
speed
Changing
the unit
AD4212C
Unnecessary
Cable included with the
weighing device
○
○
○
○
○
○
×
×
×
○
○
○
×
○⋆3
○
○
AD4212D
⋆
6
Connector for
A&D’s external
display
Unnecessary
Cable included with the
weighing device
○
○
○
○
○
○
×
×
○
○
○
○
×
○
○
Connector for the
PC/PLC
Unnecessary
AX-KO4472-1000
○
×
○
AD4212A/B
Unnecessary
AX-KO1710-200
○
△⋆4
×
×
×
○
×
×
×
×
○
×
×
○
×
○
GX-A
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
○
○
○
×
○
×
○
○
○
○
GF-A
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
○
○
×
×
○
×
○
○
○
○
FZi, HR-AZ
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
×
×
○
×
○
×
○
○
○
○
FXi, HR-A
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
×
×
×
×
○
×
○
○
○
○
GX, GX-K, GP
Unnecessary
AX-KO1710-200
○
△⋆4
×
×
×
○
×
×
○
×
○
×
○
○
×
○
GF, GF-K, GP
Unnecessary
AX-KO1710-200
○
△⋆4
×
×
×
○
×
×
×
×
○
×
○
○
×
○
BM
, GH
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
×
×
○
×
○
×
○
○
×
○
HR-i
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
×
×
×
×
○
×
○
○
×
○
GR
Unnecessary
AX-KO1710-200
○
△⋆4
×
×
×
○
×
×
○
×
×
×
○
○
×
○
HR
HR-03
(Included with
weighing device
)
AX-KO1710-200
○
△⋆4
×
×
×
○
×
×
×
×
○
×
○
○
×
○
FC-i
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
×
×
×
×
×
×
×
×
○
×
×
HC-i
HC-03i
AX-KO1786-200
○
△⋆4
×
×
×
×
○
○
×
×
×
×
×
○
×
×
Eki, Ewi
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
○
×
×
×
×
×
×
○
○
×
×
EJ, EJ-B
EJ-03
AX-KO2466-200
○
△⋆4
×
×
×
〇
×
×
×
×
×
×
○
○
×
×
EK-L
Unnecessary
AX-KO2466-200
○
△⋆4
×
×
×
〇
×
×
×
×
×
×
○
○
△⋆5
×
HV-CWP
HVW-03CWP
AX-KO3285-320
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
○
○
×
〇
HV-C, HV-CP,
HW-C, HW-CP
HVW-03C
AX-KO2466-200
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
○
○
×
〇
HV-G, HW-G,
HW-WP
Unnecessary
AX-KO1786-200
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
○
○
×
×
FG
FG-23 / FG-24
AX-KO1786-200
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
×
○
×
×
FS-i
FS-03i
AX-KO3285-320
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
○
○
×
×
SC/SE
SCE-03
AX-KO3285-320
○
△⋆4
×
×
×
〇
×
×
×
×
×
×
×
○
×
×
SW
SW-03
AX-KO3285-320
○
△⋆4
×
×
×
×
〇
〇
×
×
×
×
○
○
×
×
⋆1
.
When transferring a large amount of data from a weighing device all at once (GLP output, batch output of data memory, etc.), data may be lost.
⋆2
.
If the weighing device does not have an auto power-on function or auto-start function, it is necessary to turn on the display or each weighing device by key operation after turning on the power.
⋆3.
When using the AD4212C in command mode, it is necessary to change to internal settings in advance to enter key mode.
Also, control characters beginning with “@” output from the AD4212C are not output from the AD8551R to the RS-485 side.
⋆4.
Some functions (calibration error flag) cannot be used.
⋆5.
Power can be supplied from the weighing device when the adapter is connected to the weighing device.
⋆6.
The AD4212D has two types of RS-232C connectors. When using in Modbus RTU mode, connect the connector for A&D’s external display, and when using in command mode, connect the connector for PC/PLC and RS-232C connector of the
AD8551R.