background image

 

 

 

 

Last Updated: June 19, 2018

 

 

FWS-7360 

 

Network  Appliance 

 

User’s Manual 1

st

 Ed

Содержание FWS-7360

Страница 1: ...Last Updated June 19 2018 FWS 7360 Network Appliance User s Manual 1st Ed...

Страница 2: ...n this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result...

Страница 3: ...ademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technology Expres...

Страница 4: ...Packing List Before setting up your product please make sure the following items have been shipped Item Quantity FWS 7360 1 If any of these items are missing or damaged please contact your distributo...

Страница 5: ...tailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if...

Страница 6: ...ystem s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disco...

Страница 7: ...18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working...

Страница 8: ...osion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and yo...

Страница 9: ...Preface IX Network Appliance FWS 7360 China RoHS Requirements CN AAEON Embedded Box PC Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Страница 10: ...O O O Wires Connectors for External Connections O O O O O O Chassis O O O O O O CPU RAM O O O O O O Hard Disk O O O O O O PSU O O O O O O O The quantity of poisonous or hazardous substances or element...

Страница 11: ...der CN8 12 2 4 3 LCM KeyPad Header CN9 12 2 4 4 Digital IO Pin Header CN14 12 2 5 Installing the 2 5 x2 Hard Disk Driver 14 Chapter 3 AMI BIOS Setup 18 3 1 System Test and Initialization 19 3 2 AMI BI...

Страница 12: ...43 3 8 2 IntelRCSetup Server ME Configuration 44 3 8 3 IntelRCSetup North Bridge Chipset Configuration 45 3 8 4 IntelRCSetup South Bridge Chipset Configuration 46 3 8 4 1 SATA Configuration 47 Chapter...

Страница 13: ...ppliance FWS 7360 C 2 1 Introduction 82 C 2 2 LAN Bypass Configuration 82 C 2 3 Sample Code 84 C 3 Software Reset button General Propose Input 86 C 3 1 Introduction 86 C 3 2 LAN Bypass Configuration 8...

Страница 14: ...Network Appliance FWS 7360 Chapter 1 Chapter 1 Product Specifications...

Страница 15: ...tel Denverton C3000 Series C3758 C3858 C3958 Chipset SoC System Memory DDR4 U DIMM ECC DIMM Up to 64GB Network Ethernet Intel i211 Gigabit Ethernet x 2 Marvell 88E1543 x 1 2 Port RJ45 SFP from CPU Byp...

Страница 16: ...e maxima x 2 Option IPMI Keyboard and Mouse USB USB 3 0 x 2 Miscellaneous RTC Internal RTC Watchdog Timer 1 255 steps by software programmable Software Button TPM Optional GPIO Fan 1 MTBF Hours TBD Co...

Страница 17: ...D 1 5 Grms 5 500Hz no operation Shock 10G peak acceleration 11 m sec duration operation 20G peak acceleration 11 m sec duration non operation Dimension W x D x H 430mm x 305mm x 44mm I O Interface Fr...

Страница 18: ...Network Appliance FWS 7360 Chapter 2 Chapter 2 Hardware Information...

Страница 19: ...Chapter 2 Hardware Information 6 Network Appliance FWS 7360 2 1 Dimensions System...

Страница 20: ...Chapter 2 Hardware Information 7 Network Appliance FWS 7360 Component Side...

Страница 21: ...Chapter 2 Hardware Information 8 Network Appliance FWS 7360 Solder Side...

Страница 22: ...Chapter 2 Hardware Information 9 Network Appliance FWS 7360 2 2 Jumpers and Connectors Component Side...

Страница 23: ...Chapter 2 Hardware Information 10 Network Appliance FWS 7360 Solder Side...

Страница 24: ...Chapter 2 Hardware Information 11 Network Appliance FWS 7360 2 3 Jump Settings 2 3 1 Auto Power Button JP1 Normal 1 2 Auto power on 2 3 2 3 2 Clear CMOS CN10 Normal 1 3 2 4 Clear CMOS 3 5 4 6...

Страница 25: ...B_PWSIN 2 GND 3 RESET 4 GND 5 Power LED 6 Power LED 7 HDD LED 8 HDD LED 2 4 2 CASEOPEN Pin Header CN8 Pin Signal Pin Signal 1 CaseOpen 2 GND 2 4 3 LCM KeyPad Header CN9 Pin Signal Pin Signal 1 Down 2...

Страница 26: ...Chapter 2 Hardware Information 13 Network Appliance FWS 7360 7 DIO bit7 8 DIO bit8 9 5V 10 GND...

Страница 27: ...Chapter 2 Hardware Information 14 Network Appliance FWS 7360 2 5 Installing the 2 5 x2 Hard Disk Driver 1 Unscrew the upper lid 2 Remove the four screws...

Страница 28: ...Chapter 2 Hardware Information 15 Network Appliance FWS 7360 3 Secure the HDD to the HDD bracket with eight screws...

Страница 29: ...Chapter 2 Hardware Information 16 Network Appliance FWS 7360 4 Secure the HDD bracket to the chassis with four screws 5 Connect the SATA and power cables to the lower hard disk...

Страница 30: ...Chapter 2 Hardware Information 17 Network Appliance FWS 7360 6 Connect the SATA and power cables to the upper hard disk...

Страница 31: ...Network Appliance FWS 7360 Chapter 3 Chapter 3 AMI BIOS Setup...

Страница 32: ...eck the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to s...

Страница 33: ...the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press...

Страница 34: ...Chapter 3 AMI BIOS Setup 21 Network Appliance FWS 7360 3 3 Setup Submenu Main...

Страница 35: ...Chapter 3 AMI BIOS Setup 22 Network Appliance FWS 7360 3 4 Setup Submenu Advanced Options summary Case Open Warning Disabled Optimal Default Failsafe Default Enabled Clear Case Open detecting function...

Страница 36: ...ll not be available Pending operation None Optimal Default Failsafe Default TPM Clear Schedule an Operation for the Security Device NOTE Your Computer will reboot during restart in order to change sta...

Страница 37: ...2 protocol and event Physical Presence Spec Version 1 2 1 3 Optimal Default Failsafe Default Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Note some HCK tests might not support 1 3 Device...

Страница 38: ...Default Failsafe Default Console Redirection Enable or Disable Console Redirection Settings Legacy Console Redirection Legacy Console Redirection Settings Serial Port for Out of Band Management Window...

Страница 39: ...Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode Bits per second 9600 19200 38400 57600 115...

Страница 40: ...evices may Flow control None Optimal Default Failsafe Default Hardware RTS CTS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal...

Страница 41: ...ion of Legacy OS and Legacy OPROM Messages Resolution 80x24 Optimal Default Failsafe Default 80x25 On Legacy OS the Number of Rows and Columns supported redirection Redirection After POST Always Enabl...

Страница 42: ...management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation Bits per second 9600 19200 57600 115200 Optimal Defau...

Страница 43: ...vent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re star...

Страница 44: ...USB Configuration Options summary Legacy USB Support Disabled Enabled Optimal Default Failsafe Default Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DI...

Страница 45: ...Chapter 3 AMI BIOS Setup 32 Network Appliance FWS 7360 3 4 4 Advanced SIO Configuration...

Страница 46: ...Device Disabled Enabled Optimal Default Failsafe Default Enable Disable this Logical Device Possible Use Automatic Settings Optimal Default Failsafe Default IO 3F8 IRQ 4 DMA IO 2C8 IRQ 11 DMA Allow u...

Страница 47: ...s nDisabled FAN is always running with full speed FAN Control Mode Automatic Mode Optimal Default Failsafe Default Manual Mode Manual Mode Depends on PWM Duty nAutomatic Mode FAN Speed is depends on C...

Страница 48: ...s running with full speed FAN Control Mode Automatic Mode Optimal Default Failsafe Default Manual Mode Manual Mode Depends on PWM Duty nAutomatic Mode FAN Speed is depends on CPU Temperature Spin PWM...

Страница 49: ...FAST BLINK LAN Bypass Status LED Mode for Power on ByPass PassTru Optimal Default Failsafe Default Configure LAN kit behavior when system in power on state Bypass Pass Through Mode for Power off ByPas...

Страница 50: ...upply mode Restore AC Power Loss Last State Optimal Default Failsafe Default Always On Always Off Select power state when power is re applied after a power failure RTC wake system from S5 Disabled Opt...

Страница 51: ...iguration Options summary DIO Port1 4 Output Optimal Default Failsafe Default Input Set DIO as Input or Output Output Level High Optimal Default Failsafe Default Low Set output level when DIO pin is o...

Страница 52: ...provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or number...

Страница 53: ...ed Enabled Optimal Default Failsafe Default Enable Disable Quiet Boot option Launch PXE Rom Disabled Optimal Default Failsafe Default Enabled Controls the execution of UEFI and Legacy PXE OpROM Boot O...

Страница 54: ...Chapter 3 AMI BIOS Setup 41 Network Appliance FWS 7360 3 7 Setup submenu Save Exit...

Страница 55: ...Chapter 3 AMI BIOS Setup 42 Network Appliance FWS 7360 3 8 Setup submenu IntelRCSetup...

Страница 56: ...ilsafe Default Enabled Enable Disable EIST GV3 and TM1 must be enabled for TM2 to be available GV3 must be enabled for Turbo Auto Enable for B0 CPU stepping all others disabled change setting to overr...

Страница 57: ...Chapter 3 AMI BIOS Setup 44 Network Appliance FWS 7360 3 8 2 IntelRCSetup Server ME Configuration...

Страница 58: ...Chapter 3 AMI BIOS Setup 45 Network Appliance FWS 7360 3 8 3 IntelRCSetup North Bridge Chipset Configuration...

Страница 59: ...Chapter 3 AMI BIOS Setup 46 Network Appliance FWS 7360 3 8 4 IntelRCSetup South Bridge Chipset Configuration...

Страница 60: ...Chapter 3 AMI BIOS Setup 47 Network Appliance FWS 7360 3 8 4 1 SATA Configuration...

Страница 61: ...7360 3 8 4 1 1 SATA 1 Options summary Enable controller Enabled Optimal Default Failsafe Default Disabled Enable or disable the Chipset SATA Controller The Chipset SATA Controller support the 2 black...

Страница 62: ...Enables Disables SATA Controller port if supported by current cpu SKU Hot Plug Disabled Optimal Default Failsafe Default Enabled Hot Plug Spin up Disabled Optimal Default Failsafe Default Enabled Spi...

Страница 63: ...Network Appliance FWS 7360 Chapter 4 Chapter 4 Drivers Installation...

Страница 64: ...ktop network appliance fws 7360 It contains all the drivers and utilities you need to set up your product Follow the steps below to install the drivers For Windows 1 Open the Step 1 LAN 22_4_0_1_CD fo...

Страница 65: ...Network Appliance FWS 7360 Appendix A Appendix A Watchdog Timer Programming...

Страница 66: ...P Mode Data Register 0x2F or 0x4F Table 2 Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This register is byte...

Страница 67: ...This parameter is represented from Note24 define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This parameter i...

Страница 68: ...work Appliance FWS 7360 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure...

Страница 69: ...ableReg EnableBit 0 Clear Watchdog Timeout Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet...

Страница 70: ...0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID SIOExitMBPn...

Страница 71: ...SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet...

Страница 72: ...Network Appliance FWS 7360 Appendix B Appendix B I O Information...

Страница 73: ...Appendix B I O Information 60 Network Appliance FWS 7360 B 1 I O Address Map...

Страница 74: ...Appendix B I O Information 61 Network Appliance FWS 7360...

Страница 75: ...Appendix B I O Information 62 Network Appliance FWS 7360 B 2 Memory Address Map...

Страница 76: ...Appendix B I O Information 63 Network Appliance FWS 7360...

Страница 77: ...Appendix B I O Information 64 Network Appliance FWS 7360 B 3 IRQ Mapping Chart...

Страница 78: ...Appendix B I O Information 65 Network Appliance FWS 7360...

Страница 79: ...Appendix B I O Information 66 Network Appliance FWS 7360...

Страница 80: ...Appendix B I O Information 67 Network Appliance FWS 7360...

Страница 81: ...Appendix B I O Information 68 Network Appliance FWS 7360...

Страница 82: ...Appendix B I O Information 69 Network Appliance FWS 7360...

Страница 83: ...Appendix B I O Information 70 Network Appliance FWS 7360...

Страница 84: ...Appendix B I O Information 71 Network Appliance FWS 7360...

Страница 85: ...Appendix B I O Information 72 Network Appliance FWS 7360...

Страница 86: ...Appendix B I O Information 73 Network Appliance FWS 7360...

Страница 87: ...Appendix B I O Information 74 Network Appliance FWS 7360...

Страница 88: ...Appendix B I O Information 75 Network Appliance FWS 7360...

Страница 89: ...Appendix B I O Information 76 Network Appliance FWS 7360...

Страница 90: ...Appendix B I O Information 77 Network Appliance FWS 7360...

Страница 91: ...Network Appliance FWS 7360 Appendix C Appendix C Standard LAN Bypass Platform Setting...

Страница 92: ...atus LED Configuration Table 1 Turth Table of Status LED STA_LED2 STA_LED1 STA_LED0 LED States 0 0 0 LED Off 0 0 1 Red 0 1 0 Red Blinking Slowly 0 1 1 Red Blinking Quickly 1 0 0 Reserved 1 0 1 Green B...

Страница 93: ...arameter is represented from Note2 bData aaeonSmbusReadByte CPLD_SLAVE_ADDRESS OFFSET switch LED_FLAG case 0 LED Off BIT2 0 BIT1 0 BIT0 0 bData bData 0xF8 break case 1 Red LED On BIT2 0 BIT1 0 BIT0 1...

Страница 94: ...e FWS 7360 BIT2 1 BIT1 1 BIT0 1 bData bData 0xF8 0x07 break case 5 Green LED Blink BIT2 1 BIT1 0 BIT0 1 bData bData 0xF8 0x05 break case 6 Green LED Fast Blink BIT2 1 BIT1 1 BIT0 0 bData bData 0xF8 0x...

Страница 95: ...scription LAN_ID3 Use for selecting which LAN kit will be configured refert to Table 1 of ID Select table of LAN kit They should be set before ACT_EN LAN_ID2 LAN_ID1 LAN_ID0 PWR_ON Use for configuring...

Страница 96: ...CPLD Slave Address 0x90 Note1 Attribute Offset SMBUS BitNum Value LAN_ID3 R W 0x01 Note2 3 Table 1 LAN_ID2 R W 0x01 Note2 2 Table 1 LAN_ID1 R W 0x01 Note2 1 Table 1 LAN_ID0 R W 0x01 Note2 0 Table 1 P...

Страница 97: ...E_ADDRESS OFFSET Set Reg01h bit3 if bLanSel 0x08 bData bData 0x08 else bData bData 0xF7 Set Reg01h bit2 if bLanSel 0x04 bData bData 0x04 else bData bData 0xFB Set Reg01h bit1 if bLanSel 0x02 bData bDa...

Страница 98: ...T Reset bData bData 0xEF else Bypass bData bData 0x10 SmbusWriteByte CPLD_SLAVE_ADDRESS OFFSET bData Apply Settings Reg01h bit7 bData SmbusReadByte CPLD_SLAVE_ADDRESS OFFSET SmbusWriteByte CPLD_SLAVE_...

Страница 99: ...on which gets its status by the AAEON SDK C 3 2 LAN Bypass Configuration Table 2 LAN Bypass relative register table Function Description BTN_STS Reading this register returns the pin level status whic...

Страница 100: ...ne Word BTN_STS This parameter is represented from Note1 define ByteBTN_STS_R This parameter is represented from Note2 Byte GET_Value Word IoAddr Byte BitNum Byte Value BYTE TmpValue TmpValue inportb...