2
4
VIGIL Cuatro
4.
Flight restriction for the pilot - Airborne
Vigil®
Cuatro
will work correctly even when used in a pressurized cabin as
long
as
the pressure differs at least ±3 hPa compared to the atmospheric air pressure at
take-off.
-Inside this zone, the Vigil®
Cuatro
is in stand-by status, measuring every
32 sec. With gradual recalibration every 2 minutes to the atmospheric air pressure.
Outside this zone, Vigil®
Cuatro
will go in fast measuring status, measuring
8 times per sec, with a fixed ground zero reference in a maximum delay of 32 sec.