Document number
205065
Version
Rev. N
Issue date
2019-02-04
Sirius OBC and TCM User Manual
Page
167
of
174
LOCK-OUT
Shows Lockout status of the
FARM.
Set to ‘0’ when FARM is not in
Lockout
Set to ‘1’ when FARM is in
Lockout
WAIT
Set to ‘1’ (Wait) indicates that all
further Type-A Transfer Frames
on that virtual channel will be
rejected by FARM until the
condition cleared.
Set to ‘0’ indicates TCM
-S is able
to accept and process incoming
Type-A Transfer Frames.
RETRANSMIT
Set to ‘1’ indicates that one or
more Type-A Transfer Frames
have been rejected.
Set to ‘0’
indicates no
outstanding Type-A Transfer
Frame rejections so far.
FARM-B COUNTER
Contains two least significant bits
of FARM-B Counter.
RESERVED SPARE
Set to ‘0’
REPORT VALUE
Contains the value of the Next
Expected Frame Sequence
Number, N(R).
10.7.6. Frame Error Control Field
If used, the checksum of the Frame Error Control Field shall be calculated using CRC with
polynomial 0x8408, LSB first, and initial value 0xFFFF over the whole TM Transfer Frame
except the two last octets.
10.7.7. Telemetry Packet
Figure 10.10 Telemetry Packet