Document number
205065
Version
Rev. N
Issue date
2019-02-04
Sirius OBC and TCM User Manual
Page
137
of
174
RMAP reply status:
Table 7-59: HKData status codes
Status code
Description
0
Success.
EINVAL
The driver for the HK device has not been initialized.
EIO
I/O error. The HK device cannot be accessed
7.12.4.17. SCETTime
Reads/sets the SCET time.
Setting the SCET time is only possible when the PPS is considered qualified, see 7.7 for
details. If set, the seconds value will be updated at the next PPS, hence the seconds value
should normally be the current seconds count + 1.
The subseconds value is ignored for write commands.
Table 7-60: SCETTime data
Byte
Type
Description
0
UINT32
SCETSeconds
4
UINT16
SCETSubSeconds
RMAP reply status (if a reply is requested):
Table 7-61: SCETTime status codes
Status code
Description
0
Success.
EINVAL
Insufficient command length.
EIO
I/O error. Reading from the SCET device failed.
7.12.4.18. UARTCommand
Send a command on the specified UART interface.
Table 7-62: UARTCommand data
Byte
Type
Description
0 - nn
Array of UINT8 UART command data