background image

Thank you for your purchase!  AA's GKM (Internal UV) is a state-of-the-art design that will help control 

green water in your aquarium. Before operating this unit, please read the following safety precautions 

and operation instructions carefully.

Instruction Booklet

Features:

- Compact Submersible design with filter pump included

- Simple Installation - NO External pipes or plumbing required

- Suction Cup mounting – no tools required

- Filtration Sponge included

- LED Signals need for bulb replacement

- Unique Patented Technology

IMPORTANT SAFETY INSTRUCTIONS:

WARNING - To guard against injury, basic safety precautions should be observed, including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS.

DANGER - To avoid possible electric shock, special care should be taken since water is employed in the 

use of aquarium equipment. 

For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized 

service facility for service or discard the appliance;

If the UV device shows any sign of abnormal water leakage, immediately unplug it from the power source.

Carefully examine the UV device after installation. It should not be plugged in if there is water on parts not 

intended to be wet.

Do not operate the UV device if it has a damaged cord or plug, or if it is malfunctioning or has been 

dropped or damaged in any manner.

Close supervision is necessary when the UV device is used by or near children.

To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, 

and the like.

Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, 

and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.

Do not use the UV device for other than intended use. The use of attachments not recommended or sold 

by the manufacturer may cause an unsafe condition.

Do not install or store the UV device where it will be exposed to the weather or to temperatures 

below freezing.

Make sure an UV device mounted on a tank is securely installed before operating it.

Read and observe all the important notices on the UV device.

If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less 

amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord 

so that it will not be tripped over or pulled.

For the US version, this appliance has a polarized plug (one blade is wider than the other). As a safety 

feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, 

reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord 

unless plug can be fully inserted. Do not attempt to defeat this safety feature.

Always unplug from main supply before doing any maintenance. Do not plug or unplug any power supply 

when hands are wet.

Do not use or repair this product by yourself if the power cord is damaged. These are to be repaired or 

replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.

P1

ENGLISH 

Содержание AA03W-UVC

Страница 1: ...t moving parts or hot parts such as heaters reflectors lamp bulbs and the like Always unplug an appliance from an outlet when not in use before putting on or taking off parts and before cleaning Never...

Страница 2: ...que housing SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS 1 Carefully remove the unit from the packing materials Check for damage If damaged return product to your retailer immediately 2 Identify...

Страница 3: ...nge Cartridge CLEAN IMPORTANT Always unplug before carrying out any maintenance Cleaning Filter Pump and filtration sponge 1 Remove Lamp Assembly from your aquarium 2 Remove and rinse filtration spong...

Страница 4: ...the filter pump doesn t work Clean Blue inlet filter of debris Check connection of plug Clean the filter pump See Maintenance If the UV lamp doesn t work Check connection of plug If the LED on the con...

Страница 5: ...se si le dispositif UV est utilis pr s des enfants ou par des enfants Pour viter les accidents ne pas toucher pas les pi ces en mouvement ou les parties chaudes telles chauffe eau r flecteurs ampoules...

Страница 6: ...qu e dans une carcasse tanche prot g e opaque CONSERVEZ CES INSTRUCTIONS INSTRUCTIONS D INSTALLATION 1 Retirez d licatement l unit des mat riaux d emballage V rifiez qu il n est pas endommag Si c est...

Страница 7: ...ntr e PROPRE IMPORTANT D branchez toujours le c ble avant d effectuer tout entretien Nettoyage de la pompe filtrante et de l ponge de filtration 1 Retirez l assemblage de la lampe de votre aquarium 2...

Страница 8: ...nte ou la pompe filtrante ne fonctionne pas Nettoyez le filtre d entr e bleu anti d bris V rifiez la connexion de la fiche Nettoyez la pompe filtrante voir Entretien La lampe UV ne fonctionne pas V ri...

Страница 9: ...P9 AA AA UV LED UV UV UV UV UV UV UV UV...

Страница 10: ...P10 Fig 1 Fig 2 U UV AA UV 1 2 a 1 UV LED b 1 3 UV 4 UV UV 5 6 UV LED UV...

Страница 11: ...P11 Fig 3 Fig 4 AA03W UVC UV UV UV AAUV3W 200 UV 180 UV 4000 6000 UV GKM 8 3 5 1 UV 2 3 4 5 6 UV LED UV LED UV LED UV UV UV...

Страница 12: ...P12 UV UV LED 80L 20US Ga 9W UV 14 AA AA003M LED UV Fig 5 www aa aquarium com AA info aa aquarium com 1 2 UV 3 4 UV AA03W UVC AAUV3W UV Ref AAUV3W IB EF_E02...

Отзывы: