R-30 SRM
2.2. Installation procedure
1.
Install the valve as indicated by the arrow on the valve bonnet, indicating flow direction [
1
].
2.
In addition of the control valve it is recommended to install the following valves:
Isolation valves upstream and downstream of the control valve [
12 &12a
].
Air valves upstream and downstream of the control valve [
15
].
Quick pressure relive valve downstream of the control valve [
16
].
3.
Turn the
3
-way manual selector ball valve [
3
] to Close position and turn on the water supply to the valve.
4.
Check for leaks; tighten bolts & fittings, if necessary.
5.
Turn the adjusting screw of both Pilots [
2a
], [
2
b] counter-clockwise until there is no pressure on their springs.
6.
Close the
2
isolation valves [
12 &12a
].