R-30 S
2.2. Installation procedure
1.
Install the valve as indicated by the arrow on the valve bonnet, indicating flow direction [
1
].
2.
It is recommended to install isolation valves upstream and downstream of the control valve [
2
].
3.
Close the
2
-way outlet ball valve [
3
B], and turn on the water supply to the valve.
4.
Check for leaks; tighten bolts & fittings, if necessary.
5.
Turn adjusting screw [
4
A] clockwise until the screw head touches the pilot's bonnet.
6.
Close the
2
isolation valves [
2
].
Содержание Eliptix R-30 S 2W