Страница 1: ...MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED POWER VENT GAS MODELS ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED HYBRID GAS WAT...

Страница 2: ...OPERATING INSTRUCTIONS 33 Display Panel 33 Wiring Diagram 35 Lighting Instructions 36 Heat Cycle Definitions 37 Temperature Regulation 38 Unique Hybrid Features 39 Temperature Regulation 41 Constant O...

Страница 3: ...appliance can cause low level exposure to some of the substances listed in the act IMPORTANT DEFINITIONS Qualified Installer or Service Agency Installation and service of this water heater requires a...

Страница 4: ...4 www hotwater com GENERAL SAFETY...

Страница 5: ...rough the hose The condensate lines must be able to flow freely to an appropriate drain Do not allow condensate lines to become crimped closed Analyze the entire vent system to make sure that condensa...

Страница 6: ...ional Fuel Gas Code ANSI Z223 1 NFPA 54 and the National Electrical Code NFPA 70 Documents are available from Canadian Standards Association 5060 Spectrum Way Mississauga Ontario Canada L4W 5N6 NFPA d...

Страница 7: ...www hotwater com 7...

Страница 8: ...Cold Water Inlet F Expansion Tank G Vent Termination Elbow H Access Door Heat Engine I Earthquake Strap J Power Cord K Main Manual Gas Shutoff Valve L Gas Supply M Sediment Pocket N Condensate Tube O...

Страница 9: ...is acidic or otherwise impure the water supply must be treated with approved methods in order to ensure full warranty coverage Problems resulting from the forma tion of scale are not covered by the wa...

Страница 10: ...nted gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or l...

Страница 11: ...ater piping DO NOT use any pumps valves or fittings that are not compatible with potable water DO NOT use valves that may cause excessive restriction to water flow Use full flow ball or gate valves on...

Страница 12: ...rical controls used inside the gas control of this water heater are polarity sensitive Ensure the electrical supply is connected correctly in the receptacle box Failure to connect correctly will preve...

Страница 13: ...se or store flammable products such as gasoline solvents or adhe sives in the same room or area near the water heater Keep flammable products 1 far away from heater 2 in approved containers 3 tightly...

Страница 14: ...ndling any kind of sheet metal product Tabs have been provided on each side of the rear portion of the shroud The top and bottom of each tab must be cut and gently bent inwards thus allowing the strap...

Страница 15: ...twater com 15 Screws Screws Top Casing Front FIGURE 7 Screws FIGURE 8 FIGURE 9 After the heater has been positioned and the earthquake straps have been installed re assemble the shroud in the reverse...

Страница 16: ...rrier etc additional air may need to be provided using the methods described in Appliances in Confined Space that follows APPLIANCES IN CONFINED SPACES CONFINED SPACE is a space whose volume is less t...

Страница 17: ...1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 13 3 When communicating with the outdoors through horizontal ducts each opening shou...

Страница 18: ...g dishwashing cleaningandothersanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderl...

Страница 19: ...a water softener before the water heater system If you are installing a water filtering system use a 5 micron filter to reduce particles that can potentially cause nuisance shutdown problems and prol...

Страница 20: ...be of material listed for hot water distribution Shall be installed so as to allow complete drainage of both the temperature pressure relief valve and the discharge pipe Shall terminate a maximum of 6...

Страница 21: ...hut off valve and control valve to permit servicing of the unit The appliance and its gas connections must be leak tested before placing the appliance in operation Use a leak test solution not a match...

Страница 22: ...9007441005 Rated inputs are suitable up to 11 000 ft 3 352m elevation Consult the factory for installation at altitudes over 11 000 ft 3 352m WARNING THIS HIGH EFFICIENCY WATER HEATER IS CERTIFIED FOR...

Страница 23: ...Fuel Gas Code and local codes PLANNING THE VENT SYSTEM Plan the route of the vent system from the exhaust elbow to the planned location of the vent terminal 1 Layout total vent system to use a minimu...

Страница 24: ...alent to PVC DWV fittings meetingASTM D 2665 Use CPVC fittings ASTM F 438 for CPVC pipe and ABS fittings ASTM D 2661 3311 forABS pipe If CPVC or ABS pipe and fittings are used then proper cement must...

Страница 25: ...T OUTLET WHICH WILL CAUSE IMPROPER OPERATION WITH SOME INSTALLATIONS IT IS RECOMMEND TO INSTALL A CONDENSATE PUMP NOTE Barbed fitting not required if hard piping is used to drain condensate CONDENSATE...

Страница 26: ...mark both the inside and outside wall Align the holes by drilling a hole through the center of the template from the inside through to the outside The template can now be positioned on the outside wal...

Страница 27: ...PREVENT BLOCKAGE OR ICE BUILDUP BRACKET EQUIVALENT VENT LENGTH MEASURED FROM THIS POSITION FIGURE 27 Before completing the installation of the venting system be sure to read the sections of this manu...

Страница 28: ...ing materials that you are about to use C Know the reputation of your manufacturer and their products D Know your own qualifications or those of your contractor The solvent welding technique of joinin...

Страница 29: ...ONLY NATURAL BRISTLE 3 MAKING THE JOINT A Cutting Pipe must be squarely cut to allow for the proper interfacing of the pipe end and the fitting socket bottom This can be accomplished with a miter box...

Страница 30: ...joint will have sufficient cement to make a bead all the way around the outside of the fitting hub The fitting will have a tendency to slide back while the cement is still wet so hold the joint toget...

Страница 31: ...WARNING VENT HOOD S MAY BE EXTREMELY HOT DURING OPERATION FIGURE 31 CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY COLD AREAS THE MAXIMUM PRACTICAL DISTANCE BETWEEN...

Страница 32: ...procedure once it has started After a successful calibration the heater will go into standby mode During the calibration if the call for heat ends the calibration was not completed and the E36 error m...

Страница 33: ...played if the water heater is either in the lock or unlock condition The Icon is composed of 3 components the base a locked and an unlocked arc Operating Modes Operating modes are Boost for peak deman...

Страница 34: ...he set point and pressing the Down button will decrease the set point NOTE The Temperature Set point cannot be adjusted beyond the limits of the current Mode selected Burner in Operation When the burn...

Страница 35: ...rograming J1 Flame J5 Water Valve Water Flow J8 Thermistors J9 RS 485 J10 UIM Setting J11 High Temp SW Water Valve Water Flow Sensor BROWN YELLOW BLACK WHITE Flame Sense Rod YELLOW BLACK BLACK BLACK B...

Страница 36: ...f the appliance will not operate follow the instructions TO TURN OFF GAS TO APPLIANCE and call your technician or gas supplier DANGER Hotter water increases the risk of scald injury Consult the instru...

Страница 37: ...g the first stage of the post purge mode high speed fan operation conditions for a new call for heat are met then the system will allow the state change to Initial call for heat only after the first s...

Страница 38: ...CONTROL WATER TEMPERATURE HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHER AND LAUNDRYUSECANCAUSESCALDBURNSRESULTING IN SERIOUS PERSONAL INJURY AND OR DEATH THE TEMPERATURE AT WHICH INJURY OC...

Страница 39: ...0 C Energy Saver Mode is selected for all other Temperature set point values Three LED s are used to indicate the Operating Mode Selection Vacation Mode Yellow LED Energy Saver Mode Green LED Boost Mo...

Страница 40: ...temperature reaches the maximum design temperature for the venting used This switch should reset to the closed position when the vent pipe temperature cools sufficiently Opening Temperature is approxi...

Страница 41: ...rature If a power outage occurs or the unit is energized de energized by the STANDBY symbol for re booting the controller resets to the last temperature setting After clearing a continuous lockout err...

Страница 42: ...itions Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal See CONDENSATE section OPERATIONAL CONDITIONS Smelly Water In...

Страница 43: ...of the main burner and spark generator assembly for proper flame characteristics and ignition sequences You should also check for sooting Soot is not normal and will impair proper combustion Soot buil...

Страница 44: ...k for leaks and repair as required Reconnect the electrical power to the water heater Restart the water heater following the Lighting Instructions 1 2 3 4 5 6 TEMPERATURE PRESSURE RELIEF VALVE OPERATI...

Страница 45: ...IGURE 39 Install the filter Install the clean filter Close the drain valve Open the shutoff valves on both the hot water and cold water lines Fill the tank following the instructions in the Filling Th...

Страница 46: ...Disconnect electrical power to the water heater and circulating pump Disconnect the hoses from the heat engine Disconnect hoses and circulating pump draining the cleaning solution into the pail Reconn...

Страница 47: ...C or 105 F C LED or F LED turned ON H03 Storage tank temperature H03 xxx C or F 041 or 105 41 C or 105 F C LED or F LED turned ON H04 Heat engine water flow rate H04 xxx litres minute 056 5 6 litres m...

Страница 48: ...nuous Check inlet water filter Measure the water temperature ECO switch open temperature is 85 5 C 185 14 F and close temperature is 65 5 C 149 14 F Check the ECO switch Check the ECO wire harness Cha...

Страница 49: ...3 E23 Outlet Temperature Probe is Short circuit Outlet Temperature is maximum defined temperature E24 Inlet Temperature Probe is Open circuit Inlet Temperature is minimum defined temperature E25 Inle...

Страница 50: ...but DIP switch 4 not set to normal Soft Unplug the power cord check the DIP switch 4 position and put it in ON position Increase the set point so that a call for heat occurs Drain the tank in order t...

Страница 51: ...mal expansion tank Do not plug T P valve Improperly sealed valve Check relief valve for proper operation Do not plug T P valve HOT WATER ODORS refer to cathodic protection High sulfate or mineral cont...

Страница 52: ...d Improper sized dip tube e Water heater disconnected from electrical power Check if there is any error code on the display THE WATER IS NOT HOT ENOUGH The temperature is set too low a Check unit s te...

Страница 53: ...pipe connections may be leaking B Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area C The temperature pressure relief va...

Страница 54: ...Cold In N Drain Valve O Tank Thermistor Probe P Front Door Lock Hook Cam Q Shroud Right Side Tank Assembly Door R Display Subassembly S Heat Engine T Cover Front Flue Gas Return U Hi Limit Temperatur...

Страница 55: ...www hotwater com 55 R O N M L K J I H G F E D C B A T Q S P 12 U 10 7 6 5 4 3 2 1 Z Y X W V 11 9 8 13...

Страница 56: ...179015 Drain trap assembly condensate 9007205005 Heat engine assy 9007206005 Gas valve 9007207005 Diptube J 3 4 return 9007208005 Transformer 9007209005 Hi limit Fuse 9007210015 Switch High Temp 90072...

Страница 57: ...of hardness is not acidic or otherwise impure Problems resulting from scale formation are not covered by the warranty Any accident to the water heater or any part thereof including freezing fire floo...

Страница 58: ...58 www hotwater com NOTES...

Страница 59: ...www hotwater com 59 NOTES...