42
www.hotwater.com
316888-001 Rev. 00 dRaFt Jun 28 245
If an error code is displayed, or odd behavior of the unit occurs, the
fi
rst corrective action should be to “Cycle the Power”:
Unplug the 120Vac power cord and after 5 seconds plug it in again. If this doesn’t clear the fault, proceed with the
“Remedy” in the following table (Table 5).
If wire harness checking is required, examine the integrity of wires themselves, the connector housings, the integrity of
the terminals as well as condition of the crimps.
Fault
Code
Displayed
Description
Cause
Lockout
type
Remedy
E01, E02
Invalid Rated
KBtu/Model Type.
Control detects that the
con
fi
guration selected is not
de
fi
ned or the con
fi
guration
has never been set.
Continuous
Change the main controller board
(board).
E03, E04,
E05, E06
Main Valve Relay
Out Of Sequence.
Control detects that a relay
used to enable the Main
Valve has failed in either the
open or closed position.
Soft
Change the board.
E07
Flame Detected.
Flame detected when no
fl
ame was expected.
Soft
Check the
fl
ame rod.
Check the
fl
ame wire harness.
Change the board.
1.
2.
3.
E08
ECO switch is
open.
Control detects that the
ECO switch is open,
preventing power to the
Main Valve.
Continuous
Measure the water temperature.
ECO switch open temperature
is 85±5ºC (185±14ºF) and close
temperature is 65±5ºC (149±14ºF).
Check the ECO switch.
Check the ECO wire harness.
Change the board.
1.
2.
3.
4.
E09
High temperature
Vent Switch Open.
Control detects that the High
Temperature Vent Switch is
open, preventing power to
the Main Valve.
Continuous
Measure the water temperature.
High Vent Switch open temperature
is 74±2.8ºC (165±5ºF) and close
temperature is 57±2.8ºC (135±5ºF).
Check the switch.
Check the High Vent Switch wire
harness.
Change the board.
1.
2.
3.
4.
E10
120Vac too high.
120Vac > Overvoltage Limit.
Auto Reset
Nominal voltage is 120Vac.
Overvoltage limit is 132Vac,
Undervoltage limit is 102Vac.
Check the power cord.
Check the wall outlet.
Measure the voltage at the board
connector J7 between pin1 and pin
3. If the voltage is between limits,
change the board.
1.
2.
3.
E11
120Vac too low.
120Vac < Undervoltage
Limit.
E12
Blower Current
abnormal.
Blower Current meets
requirements for a
completely blocked
fl
ue.
Soft
Check the venting system. If the
venting system is clear, recalibrate
the unit.
Check the blower wire harness.
Change the blower.
Change the board.
1.
2.
3.
4.
E13
Blower Current meets
requirements for a partially
blocked
fl
ue.
E14
Blower Current meets
requirements for a non-
heating blocked
fl
ue
evaluation.
TABLE 5
Содержание HYB-90N
Страница 4: ...4 www hotwater com 316888 001 Rev 00 dRaFt Jun 28 245 GENERAL SAFETY...
Страница 25: ...316888 001 Rev 00 dRaFt Jun 28 245 www hotwater com 25 FIGURE 31...
Страница 52: ...599 Hill Street West Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwater com...
Страница 106: ...54 www hotwater com R O N M L K J I H G F E D C B A T Q S P 12 U 10 7 6 5 4 3 2 1 Z Y X W V 11 9 8 13...
Страница 109: ...www hotwater com 57 NOTES...
Страница 110: ...58 www hotwater com NOTES...
Страница 111: ...www hotwater com 59 NOTES...
Страница 112: ...599 rue Hill Ouest Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwater com...