General

Indicates a potentially hazardous situation which, if not avoided, could 
result in serious injury or death.

Indicates a potentially hazardous situation which, if not avoided, may 
result in minor or moderate injury or property damage.

This is the safety alert symbol. This symbol alerts you to potential hazards 
that can hurt you and others. All safety messages will follow the safety 

alert symbol with either the word “DANGER” or “WARNING”.

DANGER

WARNING

CAUTION

Important

These instructions have been written as a guide for the proper installation and operation of 
your water heater. A. O. Smith will not accept any liability where these instructions have 

not been followed. However, for your safety and to avoid damage caused by improper 
installation, it is recommended that water heater must be installed by a Qualified Service 
Technician.
Before proceeding with the installation instructions:
 

1.  

Inspect the water heater and its component parts for possible damage. Do Not   

 

   

install or attempt to repair any damaged component parts. If you detect any    

 

   

damage in the water heater, please contact the Dealer from where the water    

 

   

heater was purchased or call A. O. Smith Customer care.

 

2.  

Verify that the voltage being supplied corresponds to that which is marked on the  

 

   

water heater manual.

WARNING

DO NOT use this water heater if any part is under water. Immediately contact a Qualified 
Service Technician to inspect the water heater and contact A. O. Smith Service personnel to 

replace any part of the control system which has been under water. Failure to follow this 
instruction can result in property damage, serious injury or death.

Safety

Your safety and the safety of your loved ones is paramount. There are several safety related 

messages in this manual, which have been provided during various steps such as the 
installation, operation and maintenance of your HSE-SDS water heater. These messages 
point out potential hazards and also educate on how to reduce any potential risks. Please 
always read and follow all safety messages as provided in this user manual.

Содержание HSE-SDS 6

Страница 1: ...day 9 am to 6 pm For calls registered at A O Smith call centre before 4 pm only Not available on public holidays and under unavoidable circumstances Available in select cities only T S E A O SMITH A O...

Страница 2: ...Factory Address A O Smith India Water Products Private Limited formerly known as A O Smith India Water Heating Private Limited Plot 300 Phase II KIADB Industrial Area Harohalli Kanakapura Taluk Ramana...

Страница 3: ...n 6 Connecting to Water Supply 8 Operation 10 A O Smith Colour Match System 14 Troubleshooting 15 Circuit Diagram 15 Warranty 16 Jurisdiction 17 Expert Company Service 17 Service and Maintenance 19 Co...

Страница 4: ...a shipment has been delivered to you in apparent good condition but upon opening the packaging if any loss or damage has taken place while in transit inform the carrier s agent A O Smith representati...

Страница 5: ...s component parts for possible damage Do Not install or attempt to repair any damaged component parts If you detect any damage in the water heater please contact the Dealer from where the water heater...

Страница 6: ...E mm 105 130 130 F mm 258 348 383 Model HSE SDS HSE SDS HSE SDS 006 015 025 Volume L 6 15 25 Power W 2000 Voltage Frequency V Hz 230 50 Actual Stdg Loss kWh 24h 45 C diff 0 390 0 500 0 560 Reheating T...

Страница 7: ...mper or detach the safety valve from the water heater WARNING Part Description 1 Cold water inlet pipe with diffuser 2 Hot water outlet pipe 3 Safety Valve 4 Temperature Control Knob 5 Decorative Fron...

Страница 8: ...in case the pressure overshoots the preset limits Thermal Cutout If the water temperature exceeds the highest preset level the thermal cut out cuts off the power supply to assure safety Anode Rod The...

Страница 9: ...6 Do not install the water heater where water splashes on the water heater Figure 3 Figure 4 Safety Precautions CAUTION CAUTION Installation Before installing ensure that the following tools are avai...

Страница 10: ...ompletely filled with water Figure 7 Figure 8 8VH D GULOO ELW ZLWK GLDPHWHU RI PP to drill 2 holes at least 90 mm deep in the wall Fig 8 Step 3 The two holes should be aligned horizontally The horizon...

Страница 11: ...KRW ZDWHU SLSH WR WKH RXWOHW Red Cap WWDFK WKH LVFKDUJH 7XEH WR 6DIHW 9DOYH as shown in Installation Diagram Fig 11 Figure 11 Installation Diagram 3ODFH WKH ZDWHU KHDWHU RQ WKH DQJLQJ Screws using the...

Страница 12: ...the users and damage nearby objects if not properly routed to a drain W LV UHFRPPHQGHG WR RSHUDWH WKH LVFKDUJH HYHU LQ WKH 6DIHW 9DOYH RQ D UHJXODU EDVLV WR ensure that there are no blockages and als...

Страница 13: ...leakage In case of a leakage drain the water heater completely repair the leaking joint and then refill the water heater CAUTION This water heater should not be operated with insufficient amount of wa...

Страница 14: ...done CAUTION Connect the water heater using independent sockets do not use any adapters Use multimeter to check whether the live line and neutral line are not reverse to ensure complete safety Before...

Страница 15: ...indicator lamp When the temperature of the water drops by 5 C from the set temperature due to usage of water the water heater again enters into the heating mode Figure 15 Heating mode Standby mode Wh...

Страница 16: ...drain If it is below freezing temperature you will need to unplug the unit and drain it Switchofftheelectricsupplytothewater heater Openthehotwaterfaucetuntilthewater runscool Closecoldwatersupply Dra...

Страница 17: ...A O Smith Customer Care Centre 1800 103 2468 to register your product within 60 days of purchase and ask for one of the Decorative Front Panel colour options which will be delivered to you at no cost...

Страница 18: ...er Turn ON electrical switch Heating indicator lamp does heater not glow Thermostat does not shut OFF Thermostat is not functioning Call Customer care centre Improper thermostat calibration Call Custo...

Страница 19: ...ted only to defects which occur under conditions of proper installation normal operation and under proper use It excludes defects occurring because of abuse faulty care or maintenance and repairs alte...

Страница 20: ...e by paying the Labour Cost and Spares needed to attend to that Service or Complaint Call at the prevailing Company rates Such service will be rendered by the Company in towns or places where the Com...

Страница 21: ...____________ Ph _______________ Mobile _____________________ E mail ___________________ Warranty Card Company Copy to be sent back to the Company Dealer s Stamp and Signature Invoice Number __________...

Страница 22: ...Phase II KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District Karnataka 562 112 India Toll Free No 1800 103 2468 Website www aosmithindia com CIN U31909KA2006PTC040282 For Service need...

Страница 23: ......

Страница 24: ...as A O Smith India Water Heating Private Limited Plot 300 Phase II KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District Karnataka 562 112 India Toll Free 1800 103 2468 n Website www ao...

Отзывы: