background image

6

IMD -0299

EES 30, ...120

1.3.2  Dimensions EES 52, EES 66, EES 80 en EES120

TYPE

EES 52 

EES 66 

EES 80 

EES 120

Total height 

mm 

 1370 

1530 

1540 

1620

Diameter of the apparatus

D

mm 

510

520 

570 

710

Height of drain tap

R

mm 

95

95

95

110

Height of T&P plug

S

mm 

1210 

1360 

1330

1385

Connection cold water

1

ø

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

Connection hot water

2

ø

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

Connection T&P plug 

3

ø

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

Connection drain tap

4

ø

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

¾” -14 NPT

Tankage

lt. 

190 

250

300

450

Number of elements

stuks 

2

2

2

Capacity (220 V) 

kW 

2,5 

2,5 

2,5 

2,5

Capacity (240 V) 

kW 

3,0 

3,0 

3,0 

3,0

Heating time up to 60°C (220/240 V)* 

min 

255/214 

343/289 

416/350

625/525

Heating time up to 40°C (220/240 V)* 

min

153/129 

206/173

250/210 

375/315

Draining tap capacity at 60°C first hour 

(220/240)** 

lt/uur 

201/209

244/252

286/294

407/415

Draining tap capacity continuous, at 60°C 

(220/240)** 

lt/uur 

44/52

44/52

44/52

44/52

Draining tap capacity at 40°C first hour 

(220/240)** 

lt/uur 

335/349 

406/420 

447/491 

679/693

Draining tap capacity continuous, at 40°C 

(220/240)** 

lt/uur 

73/87

73/87

73/87

73/87

Weight

kg 

69

89

103

161 

Содержание EES - 30

Страница 1: ...1 INSTALLATION AND USER INSTRUCTION UNITED KINGDOM IRELAND ELECTRIC WATER HEATERS MODELS EES 30 EES 66 EES 40 EES 80 EES 52 EES 120...

Страница 2: ...2...

Страница 3: ...ance 8 2 3 1 Sacrificial anode 8 2 3 2 Decalcification 8 2 4 Measures to be taken at moments of failures 8 2 5 Safety thermostat 9 2 6 Water temperature not right 9 2 6 1 Warm water temperature too hi...

Страница 4: ...thick FFC insulating layer surrounded by a steel casing is preventing it from an unnecessary loss of heat As soon as the heater will be competely filled with water it will continually be under the pr...

Страница 5: ...plug 3 14 NPT 14 NPT Connection drain tap 4 14 NPT 14 NPT Tankage 115 155 Number of elements 2 2 Capacity 220 V 2 5 2 5 Capacity 240 V 3 0 3 0 Heating time up to 60 C 220 240 V 158 133 208 175 Heatin...

Страница 6: ...PT 14 NPT 14 NPT 14 NPT Tankage lt 190 250 300 450 Number of elements stuks 2 2 2 2 Capacity 220 V kW 2 5 2 5 2 5 2 5 Capacity 240 V kW 3 0 3 0 3 0 3 0 Heating time up to 60 C 220 240 V min 255 214 34...

Страница 7: ...e electric installation will always be effected by an authorised installer as well as according to the general and current regulations of the electricity works This heater will have to be provided wit...

Страница 8: ...e to be done by using appropriate means If you need more detailed information thereon the relevant instructions are available 2 4 Measures to be taken at moments of failures Whenever there is a failur...

Страница 9: ...whether there are leakage s and or open taps 3 Check whether the wiring is still correctly connected 4 It s possible that the consumption of hot water is higher than it had been calculated originally...

Страница 10: ...ing completely the electric circuit the water temperature having reached 95 C After this temperature will have fallen by 20 C the thermostat can be reset again In the case of another intervention of t...

Страница 11: ...utton There is no hot water supply left Reduce the hot water consumption Admit the necessary heating time The plug is out of the socket Put the plug into the socket The cause cannot be determined Turn...

Страница 12: ...ronment h that the boiler has been provided with an inlet combination approved by an authorised body of suf cient capacity not greater than the operating pressure indicated on the boiler and if applic...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16 0310 140 R0...

Отзывы: