Installation
26
Instruction manual ADM
3
is
3.8
Electrical
connection
Warning
The installation should be carried out by an authorised installation engineer,
in compliance with general and local regulations (1.3 "Regulations").
3.8.1
Preparations
Caution
The appliance is phase-sensitive. It is
absolutely essential
to connect the
mains live (L) to the live of the appliance, and the mains neutral (N) to the neutral
of the appliance.
Caution
There must also be
no potential difference
between neutral (N) and earth
( ). If this is the case, then an isolating transformer must be applied in the
supply circuit.
For more information or to order an isolating transformer, please contact A.O.
Smith Water Products Company.
The figure shows a view of the electrical connector block, and the table shows
the appropriate connections.
Connector block
1. In preparation, first remove the protective cover from the control column:
2. Undo the 4 screws (A).
3. Remove the protective cover (B) from the electrical part.
The connector block (C) is now visible.
Note
Please consult (14.2 "Electrical diagram") the appropriate electrical
diagram for details of the connections of the electrical components.
Terminal block
Legend
A. screws
B. protective cap
C. connector block
A
B
C
8
1
IMD-0506 R0
Mains power
Flue gas
thermostat
Unused
L
1
N
L
1
L
2
N
1
2
3
4
5
6
7
8
Содержание ADM - 40
Страница 4: ...4 Instruction manual ADMP gis...
Страница 32: ...Installation 32 Instruction manual ADM 3 is...
Страница 36: ...Conversion to a different gas category 36 Instruction manual ADM 4 is...
Страница 42: ...The control panel 42 Instruction manual ADM 7 gis...
Страница 44: ...Status of the appliance 44 Instruction manual ADM 8 gis...
Страница 46: ...Starting and running 46 Instruction manual ADM 9 gis...
Страница 48: ...Shutting down 48 Instruction manual ADM 10 gis...
Страница 59: ...Instruction manual ADM 59 is 14 Appendices 14 1 Introduction This section gives the electrical diagram...
Страница 62: ...Appendices 62 Instruction manual ADM 14 is...
Страница 64: ...0311 812 1 1 UK Index Instruction manual ADMP...