NRP620-9 OMEPAPV20161017 (ENGLISH) REV 1
Page 25 of 42
ELECTRICAL WIRING
WARNING
For your personal safety, turn off electrical power at the service entrance before making any electrical
connections.
All electrical work must conform to your local codes and ordinances or with the National Electrical
Code. If you are not familiar with wiring and codes in general, have a competent electrician do this
job.
Make connections to the furnace junction box (see below) from a 120VAC, 15 amp fused, and
grounded circuit that has been tested and confirmed to be wired correctly.
Connect Ground to the green ground lug in the furnace junction box.
Connect 120VAC “neutral” to the white power connection in the furnace junction box.
Connect 120VAC “power” to the black power connection in the furnace junction box.
Solder and tape, or use wire nuts on all connections.