background image

Owner’s Manual  

 7

Stereo Tube Mic Pre, MP-2A

 

Functions

 (continued)

 

 

 

 

 

Back

 

 

 

 

 

 
 

12 

AC Power Connector

  - For electrical outlet (Caution: please check to see what Voltage your MP-2A is set to). If 

the Voltage Box is not marked according to your country’s code please notify A Designs before powering up.

 

 

13 

Fuse Amperage

  - These are placed on the MP-2A to indicate which voltage your unit is set up for. USA Voltage 

should be set to 120v. For export to countries with 220v, the correct box should be marked at the back of the unit. 
If not marked or marked incorrectly, please notify A Designs before you turn your unit on!

 

 

14 

Fuse Box

  - This box acts as a fuse container draw. The Fuse draw will slide in and out for easy access to change 

your fuse, as necessary.

 

 

15 

Heat Vents

  - Allow the flow and circulation of air to cool the tubes and transformers.

 

 

16 

XLR Outputs

  (balanced) - The XLR output is balanced out and you have the option to change the output 

ohms from the face of the MP-2A (600 ohms/ 10k) by using the OUTPUT Switch located on the front panel of 
the MP-2A. XLR’s are clearly marked indicating which Channel is being used.

 

 

17 

XLR Inputs

  (balanced) - The XLR input is used for Microphones. You can use the inputs for other instruments.

 

If you are using a condenser Microphone, please make sure your Phantom Power is in the on position. The 
Phantom Power switch is located on the front panel. (See Illustration 1). XLR’s are clearly marked indicating 
which Channel is being used.

 

 

18 

Serial Number

  - If this serial number is removed or tampered with, your warranty will be void.

 

 

 
 

The MP-2A has a 2U rack space which fits nicely into any Studio Rack and will compliment your array.

 

 

UNIT SIZE:

 

 

Width: 

Standard 19 inches for easy Rack Mount installation. 

Height: 

Standard 3.50 inches or 2U Rack Space.

 

Depth: 10 

inches

 

Weight: 

18 lbs 8.16 kg.

 

Содержание MP-2A Series

Страница 1: ...STEREO TUBE MIC PRE MP 2A Owner s Manual ...

Страница 2: ...ited Warranty Tubes A Designs Audio Inc warrants that our hardware conforms substantially to the specifications contained in this manual when used in accordance these specifications for a period of one year from the date of original purchase from A Designs Audio Inc or its authorized dealers In case of a valid warranty claim your sole and exclusive remedy and A Designs entire liability under any t...

Страница 3: ...nwanted noise such as pops The same applies when you shut down Allow a minimum of 25 seconds for the power to drain from the tubes properly Then you can unplug your instrument or microphone Always turn your Phantom switch to the off position before plugging or un plugging your Microphone When placing the MP 2A Series in a rack we recommend using the first tier or allow one x space in order to prop...

Страница 4: ...Lamp On Off Two 2 Neutrik Combo XLR 1 4 Input Connectors Two 2 XLR Output Connectors Zero Feedback Loop Two 2 U Rack Space Two 2 CineMag Input Transformers Two 2 Custom Wound Output Transformers Two 2 6NI P Tubes Two 2 EF86 Tubes Clean and airy high end Warmth transparency and quality sound In line with our company policy of continuous development the above features are subject to change without n...

Страница 5: ...Ohm Balanced XLR Output Output Impedance 600 Ohm Switchable to 10k Maximum Level 22 dBu Output Low Z transformer balanced Frequency Response 20 Hz 60k Hz Distortion THD 08 1 Khz Power Requirements 100 120 230 VAC 42 Watts Dimensions W x H x D 19 x 3 5 x 10 Weight 18 lbs 8 16kg Shipping weight 20 lbs MP 1 17 lbs In line with our company policy of continuous development the above specifications are ...

Страница 6: ...ophone please make sure you have the Phantom Switch in the on position If you turn the Phantom Power Switch off while the Mic is still plugged in there will be a 5 second delay before it is completely off 7 Tone Switch 1 2 This switch will allow you to set your outputs to your configuration 8 Tone Switch 3 4 This switch will allow you to set your outputs to your configuration 9 Heat Vents Allow th...

Страница 7: ... the tubes and transformers 16 XLR Outputs balanced The XLR output is balanced out and you have the option to change the output ohms from the face of the MP 2A 600 ohms 10k by using the OUTPUT Switch located on the front panel of the MP 2A XLR s are clearly marked indicating which Channel is being used 17 XLR Inputs balanced The XLR input is used for Microphones You can use the inputs for other in...

Страница 8: ...ass guitars in rock pop songs and more recently vocals in chorus Another technique audio engineers use when recording an instrument in stereo is to run one side in phase and the other side out of phase This trick tends to deceive the stereo image and also defuses bass boom by canceling out frequencies It may sound unusual but surprisingly there are large numbers of published Audio CD s where this ...

Страница 9: ...A DESIGNS AUDIO INC PRO AUDIO P O Box 4255 West Hills CA 91304 USA 818 716 4153 www adesignsaudio com ...

Отзывы: