Technical Bulletin

1370

23023

code

a.b.s.

 S.r.l. (Milan) Italy

 Lombardia street 310, 20861 Brugherio

Tel. +39 039 839631 - Fax. +39 039 8396349

e-mail:[email protected] - www.absfire.it - Capital 2.000.000

Technical data are subject to modification

for improvements without prior notice

Data Sheet

Code

Date

Check

Rev

Pag.

Marine Con.Box

23023

25/05/15

benz

3/

benz

1/5

Control Box 

23023

for boat or car fire system actuator Usually fixed on the boat dash board

Central unit CPU

Weight: 230 g

WIRING DIAGRAM

Dash board
Remote unit

Weight: 57 g

TECHNICAL DESCRIPTION

CHASSIS IN ABS, IP 65

The central unit and the dash board remote unit are
manufactured with materials immunes to the marine
environment and supplied with seal that guarantee
maximum impermeability.
Furthermore, the chassis ensures adequate heat dissipation
which allows long periods of operation.

 Maximum connection distance

- With double insulated cable

60 mt;

- With shielded twisted pair cable

150 mt.

- Very easy to use

Large backlit LCD 16X2

-

Language: Italian, English, Franch, German, Spanish.

Compact dimension

Power supply

:

12Vdc 

(500 MA)

24Vdc 

(250 MA)

Output relay

: Max 3A

Max 3A

Signal input

: N.O.

N.O.

Microcontroller

:

Advanced RISC 8bit

Comunication

:

RS485 half duplex

- Backlit LCD Display 16x2

- Acoustic and optical signal with led.

- Programmable by buttons.

INPUT

OUTPUT

Technical specification

Содержание 23023

Страница 1: ... IP 65 The central unit and the dash board remote unit are manufactured with materials immunes to the marine environment and supplied with seal that guarantee maximum impermeability Furthermore the chassis ensures adequate heat dissipation which allows long periods of operation Maximum connection distance With double insulated cable 60 mt With shielded twisted pair cable 150 mt Very easy to use La...

Страница 2: ...sfire it Capital 2 000 000 Technical data are subject to modification for improvements without prior notice Data Sheet Code Date Check Rev Pag Marine Con Box 23023 25 05 15 benz 3 benz 2 5 Electric wire diagram Electric actuator Is fixed on the valve Easyfire or Firekill R Monitoring LED resistor 1 8 K Ω at 24 V 1 2 Connector base Power supply selector 12 24Vdc ...

Страница 3: ...llow led FAULT shows an anomaly from the IN1 IN2 IN3 IN4 IN5 and according to the set delays on the outputs it will generate the activation of the OUTPUT OUT1 OUT2 OUT3 OUT4 OUT5 After activation of the outputs the yellow led FAULT will switch off and the red led EMPTY will be switched on The green led POWER indicates that the system is correctly operating and it will be switched off in case of ma...

Страница 4: ...ease from 0 99 DELAY OUTPUT 3 RX Increase from 0 99 LX Decrease from 0 99 DELAY OUTPUT 4 RX Increase from 0 99 LX Decrease from 0 99 DELAY OUTPUT 5 RX Increase from 0 99 LX Decrease from 0 99 Descriptions that appear on the display www absfire it immediately after power up OPERATING SYSTEM SYSTEM DISCHARGE COLOR SYSTEM STATUS PERFORM LED DESCRIPTION OPERATION Dash board led Status System OK Device...

Страница 5: ...z 5 5 1 2 3 4 5 6 Collegare l alimentazione ai morsetti 1 e 2 Collegare l unità remota ai morsetti 3 4 5 6 Se quest ultima si trova ad una distanza compresa tra 1 e 10 metri dalla unità centrale collegare inoltre la resistenza da 2 2 KOhm sull unità base ai morsetti 3 e 5 come indicato Connect battery to terminals 1 and 2 Connect remote unit to terminals 3 4 5 6 If Remote unit is between 1 and 10 ...

Отзывы: