background image

8e6 Corporate Headquarters (USA): 

828 West Taft Avenue Orange, CA 92865-4232 • Tel: 714.282.6111 or 888.786.7999 

Fax: 714.282.6116 (Sales/Technical Support) • 714.282.6117 (General Office)

Satellite Office: 

8e6 Taiwan: 7 Fl., No. 1, Sec. 2, Ren-Ai Rd., Taipei 10055, Taiwan, R.O.C. 

Tel: 886-2-2397-0300 • Fax: 886-2-2397-0306

Содержание ProxyBlocker MSA-004-005

Страница 1: ...GUIDE ProxyBlocker QUICK START Model ProxyBlocker MSA 004 005 Release 1 0 00 Updated 02 11 08 ...

Страница 2: ...o war ranties with respect to this documentation and disclaims any implied warranties of merchantability and fitness for a particular purpose 8e6 Technologies shall not be liable for any error or for incidental or consequential damages in connection with the furnishing performance or use of this manual or the examples herein The information in this documentation is subject to change without notice...

Страница 3: ...k Mount the Server 6 Check the Power Supply 15 General Safety Information 16 Install the Server 19 Step 1 Setup Procedures 19 Step 1A Wizard Setup Procedures 20 Step 1B Console Setup Procedures 27 Step 2 Test the ProxyBlocker Console Connection 37 Step 3 Test Filtering 38 Step 4 Set Library Updates 38 Conclusion 41 LED Indicators and Buttons 42 MSA Units 42 Regulatory Specifications and Disclaimer...

Страница 4: ...iv 8e6 ProxyBlocker Quick Start Guide ...

Страница 5: ...n Internet filtering product other than 8e6 s R3000 Enterprise Filter 8e6 ProxyBlocker tracks each user s online activity of Web based proxies and anonymizers and can be configured to block specific Web sites or service ports thereby protecting your organization against lost productivity network bandwidth issues and possible legal problems that can result from the misuse of Inter net resources ...

Страница 6: ...tors and use LED buttons for troubleshooting the unit Regulatory Specifications and Disclaimers This section cites safety and emis sions compliance information for the ProxyBlocker model referenced in this docu ment Index An alphabetized list of some topics included in this document Conventions Used in this Document The following icons are used throughout this document to call attention to importa...

Страница 7: ... Domestic US 1 888 786 7999 International 1 714 282 6111 8e6 Taiwan Taipei Local 2397 0300 Domestic Taiwan 02 2397 0300 International 886 2 2397 0300 Procedures When calling 8e6 Technologies regarding a problem please provide the representative the following information Your contact information Serial number or original order number Description of the problem Network environment in which the unit ...

Страница 8: ...containing a CD ROM with PDFs of the ProxyBlocker User Guide and ProxyBlocker Authentication User Guide The latest version of the ProxyBlocker User Guide can be obtained from our Web site at http www 8e6 com docs pba_ug pdf The latest version of the ProxyBlocker Authentication User Guide can be obtained from our Web site at http www 8e6 com docs pba_auth_ug pdf NOTES A coupler is included in the c...

Страница 9: ...al shock Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators copy machines air conditioners large fans large electric motors radio and TV transmitters and high frequency security devices Access space provided so the server power cord can be unplugged from the power supply or the wall outlet this is the only way to remove the AC power cord from the s...

Страница 10: ... the power supply will not overload any circuits Con sideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern The server is only connected to a properly rated supply cir...

Страница 11: ...avoid personal injury and property damage please carefully follow all the safety steps listed below Before installing the chassis rails Close the chassis using the chassis cover Unplug the AC power cord s Remove all external devices and connectors 1 Included in the shipping package are a pair of rail assemblies In each rail assembly locate the inner rail and the outer rail 2 Press the locking tab ...

Страница 12: ...ch of the inner rail 4 Attach an inner rail to each side of the chassis and secure the inner rail to the chas sis by inserting three Type G screws through the holes on each side of the chassis and the inner rail See the diagram below for a description of the Type G screw 5 Repeat the above steps to install the other rail on the chassis ...

Страница 13: ...ase note that the brackets are marked with Up Front Arrows front and Up Rear arrows rear 2 Secure the front short bracket marked with the Up Front arrows to the outer rail with two Type G screws See the previous page for a description of the Type G screw 3 Attach the rear long bracket to the other end of the outer rail and secure the rear long bracket to the outer rail with a Type G screw as shown...

Страница 14: ...e chassis may not slide into the rack smoothly or easily when installed the first time Some adjustment to the slide assemblies might be needed for easy installation 8 You will need to release the safety taps on both sides of the chassis in order to com pletely remove the chassis out of the rack ...

Страница 15: ...f 28 to 33 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up 1 In the package locate a pair of front short and rear long brackets Please note that the brackets are marked with Up Front Arrows front and Up Rear arrows rear 2 Secure the front short bracket marked with the Up Front...

Страница 16: ...descriptions of Type H and Type I hardware components 4 Attach the rear long bracket to the rear end of the rack and secure it to the rack with two Type H screws and Type I washers as shown below Repeat the same steps to install the other outer rail to the other side of rack 5 Measure the depth of your rack and adjust the length of the rails accordingly Then secure the rails to the chassis with Ty...

Страница 17: ...8e6 ProxyBlocker Quick Start Guide 13 6 Slide the inner rails which are attached to the chassis into the outer rails on the rack ...

Страница 18: ...d Make sure that all the components are securely fastened to the chassis to prevent components fall ing off from the chassis The rack assembly should be properly grounded to avoid electric shock The rack assembly must provide sufficient airflow to the chassis for proper cooling Please make sure that all components and all chassis covers are properly in stalled in the chassis before you install the...

Страница 19: ...m countries Power Supply Precautions Warning Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep the server operating in case of a power failure In geographic regions that are susceptible to electrical storms 8e6 highly recom mends plugging the AC power cord for the server into a surge suppressor Use appropriately rated extension cor...

Страница 20: ... heat and even fire CAUTION There are no user serviceable components inside the chassis The chassis should only be opened by qualified service personnel Never disas semble tamper with or attempt to repair the server Doing so may cause smoke fire electrical shock serious physical injury or death Do not insert objects through openings in the chassis Doing so could result in a short circuit that migh...

Страница 21: ...tions Warning Heed the following safety precautions to protect yourself from harm and the server from damage CAUTION Dangerous voltages associated with the 100 240 V AC power supply are present inside the unit To avoid injury or electrical shock do not touch exposed connections or components while the power is on To prevent damage to the server read the information in this document for selection o...

Страница 22: ...ry Do not incinerate or expose to heat above 140 F 60 C There is a danger of explosion if the battery on the motherboard is installed upside down which will reverse its polarities CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISPOSE OF THE USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS ATTE...

Страница 23: ...ocedures ProxyBlocker with AC power cord either one of two options PC monitor with AC power cord and keyboard or PC laptop computer with HyperTerminal and serial port cable and USB DB9 se rial adapter if there is no serial port on your laptop Go to Step 1A to execute Wizard Setup Procedures Administrator Console Setup Requirements The following hardware is required for the Administrator console se...

Страница 24: ... of the front panel see Fig 2 Fig 2 Diagram of chassis front panel power button at far right Once the ProxyBlocker is powered up proceed to the Login Screen instructions Serial Console Setup A Using the serial port cable and USB DB9 serial adapter if necessary connect the laptop to the rear of the chassis see Fig 1 B Power on the laptop C Power on the ProxyBlocker by dropping down the face plate a...

Страница 25: ...ole follow these procedures to create a HyperTerminal session on the serial console A Launch HyperTerminal by going to Start Programs Accessories Communica tions HyperTerminal B In the Connection Description dialog box enter any session Name and then click OK to open the Connect To dialog box ...

Страница 26: ...the serial port on the laptop probably COM1 and then click OK to open the Properties dialog box dis playing the Port Settings tab D Specify the following session settings Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control Hardware E Click OK to connect to the HyperTerminal session ...

Страница 27: ...n the Properties dialog box displaying the Connect To and Settings tabs G Click the Settings tab and at the Emulation menu select VT100 H Click OK to close the dialog box and to go to the login screen NOTE If using a HyperTerminal session the login screen will display with black text on a white background ...

Страница 28: ... Enter key to display the Password prompt C At the Password prompt type in the following s3tup r3k D Press Enter to display the System Configuration screen System Configuration Screen A At the Press the number of your selection prompt press 2 to select the setup pro cess for the System Configuration wizard B At the login prompt re enter your password s3tup r3k C Press Enter to display the Administ...

Страница 29: ...OTE See the Network screens for LAN Settings and Regional Setting in Step 1B for content included in the wizard screens B After making all entries using the wizard press X to return to the System Configura tion screen Or to verify the status of the ProxyBlocker and review the entries you made using the wizard press 1 to view the System Status screen NOTES Changing your password using option C Chan...

Страница 30: ...teway IP address specified in screen 5 Configure default gateway ProxyBlocker host name specified in screen 7 Configure host name DNS server IP address es specified in screen 6 Configure DNS servers Regional timezone setting specified in screen 8 Time Zone regional setting Current status of the ProxyBlocker Current ProxyBlocker software Version installed Library update status NOTE Modifications ca...

Страница 31: ...e link for LAN or High Speed Internet and choose Properties Windows 2000 right click the My Network Places icon and select Properties Right click the correct Local Area Connection and choose Properties Windows NT right click the Network Neighborhood icon and select Properties Windows ME right click the My Network Places icon and select Properties B Click on Internet Protocol TCP IP to highlight it...

Страница 32: ...T 5E crossover cable into the ProxyBlocker and the other end into the coupler Plug a standard CAT 5E cable into the other end of the coupler and the free end of the standard CAT 5E cable into the setup workstation C Plug the ProxyBlocker into a power source with an appropriate rating WARNING It is strongly suggested you use an uninterruptible power supply D Power on the ProxyBlocker by lowering th...

Страница 33: ... your keyboard If you receive a reply the unit is up Network Setup When the ProxyBlocker is fully booted you can configure network settings For this step you will need your network administrator to provide you the host name gateway ad dress and two unused IP addresses Access the ProxyBlocker Administrator Console A Launch Internet Explorer from the setup workstation B Type in http 1 2 3 4 88 in th...

Страница 34: ...pplication opens see image on the next page Log in to ProxyBlocker Administrator Console In the login dialog box you need to enter the generic Username and Password A In the Username field type in admin B In the Password field type in user3 C Click OK to close the login dialog box and to go to the main screen of the Proxy Blocker Administrator console ...

Страница 35: ...ProxyBlocker will use on your network Select NTP servers the ProxyBlocker will use for time synchronization with Internet clocks Indicate the region in which the ProxyBlocker is geographically located NOTE After saving your entries in each of these windows Operation Mode LAN Settings NTP Servers Regional Setting you may be prompted to restart or reboot the server Click OK to acknowledge the conten...

Страница 36: ...es in the Operation Mode window A In the Listening Device frame select the device for listening to traffic generally LAN1 B In the Block Page Device frame select the device for sending block pages to client PCs The block page device should be a different device than the one selected in the Listening Device frame LAN2 is generally used as the default device for sending block pages C Click Apply ...

Страница 37: ...cognize your account for library updates This name needs to be a valid DNS entry B Enter the LAN1 IP address and specify the subnet for LAN 1 the ProxyBlocker s first Ethernet Network Interface Card NIC You may use a non routeable IP address for the listening interface and a subnet mask of 255 255 255 255 32 bites C Enter the LAN2 IP address and subnet for LAN 2 the ProxyBlocker s second Ether net...

Страница 38: ...st name you assigned to the ProxyBlocker It is strongly suggested you document and store this information as it is now the only way of communi cating with the ProxyBlocker G Click Apply Network NTP Servers From the navigation panel click Network and choose NTP Servers from the pop up menu The NTP Servers window is used for specifying the Network Time Protocol NTP serv ers to be used by the ProxyBl...

Страница 39: ...two more NTP servers following the procedures in sub steps A and B These will be the secondary and tertiary NTP servers in order as they appear in the list box D Click Apply NOTE If the primary server fails the secondary will be used If the secondary server fails the tertiary server will be used Network Regional Setting From the navigation panel click Network and choose Regional Setting from the p...

Страница 40: ... server by using the power or reset buttons i From the navigation panel of the System section of the console click Control and select Reboot from the pop up menu to display the Reboot window ii Click the Reboot button iii From the time you click Reboot you have approximately 2 minutes to perform sub steps B through E while the ProxyBlocker goes through the reboot process B Disconnect the crossover...

Страница 41: ...ld be prompted to log into the Administrator console giving the Username and Password If you can access the ProxyBlocker Administrator console the ProxyBlocker is function ing on your network and you should proceed to Step 3 If you cannot access the ProxyBlocker Administrator console please verify the status of the LAN connection in Windows on the network workstation and then try enabling dis abli...

Страница 42: ...he activation code that was issued to you by e mail also includ ed on the product invoice NOTE Ports 20 and 21 FTP must be open for outgoing requests so that the ProxyBlocker can receive library updates Activate and Register the ProxyBlocker Be sure you have a valid host name chosen before activating your account A Open an Internet browser window and go to http www 8e6 com activate B After reading...

Страница 43: ...e before you begin using the ProxyBlocker you must perform a complete library update to ensure you have the latest library updates To download the latest library updates go to the ProxyBlocker Administrator console A Click the Library button at the top of the screen B From the navigation panel click Updates and select Manual Update from the menu C In the Manual Update to 8e6 Supplied Categories wi...

Страница 44: ...te activity NOTE You will be notified in the log when the library has been completely updated by the message Full URL Library Update has completed If this message does not yet display click View Log again to view the latest information WARNING At the conclusion of this step your ProxyBlocker will be actively filtering your network The ProxyBlocker is initially set to filter pornography sites on al...

Страница 45: ...bers To activate a default filter profile more appropriate for your operations or to specify a more limited IP range to filter consult Chapter 2 Group screen in the Global Adminis trator Section of the ProxyBlocker User Guide Refer to Chapter 1 System screen for information on how to give end users access to acceptable HTTPS sites if strict HTTPS filtering settings are used Obtain the latest Proxy...

Страница 46: ...is control panel LED Indicator Key Button Key A Power F Reset B HDD Activity G Power C LAN 1 D LAN 2 E Overheat LED indicators alert you to the status of a feature on the unit while buttons let you per form a function on the unit LED Indicator Color Condition Description Power Green On System On Off System Off HDD Amber Blinking HDD Activity Off No HDD Activity LAN 1 LAN 2 Green On Link Connected ...

Страница 47: ...mply with the limits for a Class A digi tal device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction manual may cause harmful inter...

Страница 48: ... EMC EN55022 2006 EN55024 1998 A2 2003 EN61000 3 2 2000 EN61000 3 3 2001 Product Name s Internet Appliance Product Model Number s MSA 004 005 Year in which conformity is declared 2008 All hardware components supplied in this unit s shipping carton are certified by our vendors to be RoHS compliant I the undersigned hereby declare that the equipment specified above conforms to the above Directive s ...

Страница 49: ...3 44 F FCC 43 H HyperTerminal Setup 21 I ICES 003 43 L Login screen 24 Log in to ProxyBlocker Administrator Console 30 37 LVD 43 M MSA 20 28 42 43 P Physically Connect the ProxyBlocker to the Network 36 Power Supply Precautions 15 R R3000 1 Rack Setup Precautions 6 reboot 31 36 RoHS compliant 44 S serial port cable 4 19 20 shut down 36 ...

Страница 50: ...46 8e6 ProxyBlocker Quick Start Guide U UL 43 W wizard setup 19 26 ...

Страница 51: ...8e6 ProxyBlocker Quick Start Guide 47 ...

Страница 52: ...venue Orange CA 92865 4232 Tel 714 282 6111 or 888 786 7999 Fax 714 282 6116 Sales Technical Support 714 282 6117 General Office Satellite Office 8e6 Taiwan 7 Fl No 1 Sec 2 Ren Ai Rd Taipei 10055 Taiwan R O C Tel 886 2 2397 0300 Fax 886 2 2397 0306 ...

Отзывы: