Environment 

General 

R-Series 10 units are intended for use in a commercial (not domestic) environment and should 

be operated in a clean, dust free area (e.g. a server room).  
The server is intended for operation in benign environments; that is, not subject to corrosive or 

explosive atmospheres, moisture or flammable gases. The server is non-protected against 

ingress of liquid (IPx0). The server is not designed to be subject to excessive mechanical 

shock or vibration. 
This equipment is not suitable for use in locations where children are likely to be present. 

 

Only used at altitude 

not exceeding 2000 m 

 

Only used in not-tropical 

climate regions 

Thermal 

Do not block any of the server’s air vents and ensure the ambient temperature around the 

server is compatible with the environmental characteristics stated below. 
Particularly when mounted in a rack cabinet with front or rear doors the ambient temperature 

around the unit may be higher than the ambient room temperature. 

Electrical 

Before connecting power to the unit, ensure the electricity supply is compatible with the 

electrical ratings shown here and on the product label. The server shall not be connected to an 

IT (unearthed neutral) power distribution system and the mains socket-outlet used shall 

connect to the building installation ground. 
The server is connected to and disconnected from the mains supply with the IEC 60320 power 

connectors on the rear of the unit. Both of the dual redundant PSUs should be connected when 

the server is in use. 

Connecting External Equipment 

To ensure best performance from the server and compliance with relevant EMC regulations, this 

equipment should only be used with high-quality shielded data and signal cables. 
Only equipment and accessories approved to IEC 60950-1 and SELV circuits may be 

connected to the server. All equipment and accessories shall comply to the relevant standard 

for the server’s port to which it is connected. 

Maintenance 

Air Filters 

A user-serviceable air filter is located behind the server’s front fascia. It is important to remove 

and clean or replace the filter periodically to avoid overheating. To remove the fascia first 

remove the two small screws bottom left and right, and then pull the fascia away. R-Series 10 

servers are supplied with spare filter pads. Others can be provided by your supplier.  
Replace the fascia and secure with the two screws. Servers should not be run without filters, 

since accumulations of dust inside the server can affect performance. 

Cleaning 

External casing and the front panel should be carefully wiped with a soft cloth and antistatic 

solution. 

Server internal maintenance 

Internal maintenance must only be undertaken by suitable qualified service personnel. 

Warning

: Do not operate the unit with any covers removed as the air flow through the 

unit may be compromised leading to overheating. 

Warning

: Motherboard CMOS battery replacement: Danger of explosion if incorrect battery 

used or battery incorrectly installed. Contact your supplier for further instructions. 

Any alterations to the product’s specification, including additional/alternative 

components, BIOS changes, overclocking, etc., may invalidate the warranty or impact 

the server’s performance. Additionally, such changes or modifications could cause equipment 

no longer to comply with the relevant EMC regulations, and void the user’s authority to operate 

the equipment. If in doubt, please contact your supplier. 

Electrostatic discharge (ESD) 

When handling electronic assemblies, take precautions to avoid electrostatic discharge (ESD) 

causing damage. Precautions should include the wearing of an ESD protective wrist strap and 

using antistatic bags for electronic assemblies when not installed in a server.  

PSU removal 

R-Series 10 Servers are fitted with dual redundant removable power supply units (PSUs). 

These can be replaced only with exactly matched units, as follows: 

 

To remove

: Power down the server. Remove both IEC 60320 power connectors from the 

server’s PSUs. Press the appropriate PSU’s release tab inwards and pull the handle to slide 

the power supply out of the server. 

 

To replace

: Slide the replacement power supply into the server and push firmly until it is 

fully clicks home. Refit the IEC 60320 power connectors and power on the server. 

Warning

: The IEC 60320 power connector should never be inserted into the PSU 

when the withdrawn PSU is not fitted in a server. 