background image

 
 
 

M569-3 

 

 

Medialon Showmaster 

Hardware Manual 

User Reference 

 

 

 

Содержание Medialon Showmaster Mini

Страница 1: ...M569 3 Medialon Showmaster Hardware Manual User Reference...

Страница 2: ...written authorization from 7thSense Design Ltd The information in this document is subject to change without notice 7thSense Design Ltd assumes no responsibility for errors and or omissions contained...

Страница 3: ...rols 9 2 2 4 Side Panel 9 2 2 5 Mounting 9 2 2 6 Technical Specifications 9 2 3 Showmaster LE Description 11 2 3 1 Contents of the Package 11 2 3 2 Getting Started 11 2 3 3 Front Panel Controls 12 2 3...

Страница 4: ...une 2023 2 5 4 Rear Panel 32 2 5 5 Mounting 33 2 5 6 Technical Specifications 33 2 5 7 Environment 34 2 5 8 Maintenance 35 2 6 Disposal Information All Showmaster Devices 35 3 Showmaster Maintenance 3...

Страница 5: ...Medialon Software and Plug Ins Warranty Terms and Conditions for Medialon Hardware For Medialon show control software please refer to M515 Medialon Control Systems Manual includes appendix on converti...

Страница 6: ...the ability to run or debug the project using Medialon Manager set in the appropriate mode Programming Software Number of Timelines Number of Web Panel Connections Number of Devices Showmaster Mini Me...

Страница 7: ...in 10 device batches up to a max of 50 devices This AV device controller runs Medialon Manager V6 and V7 for Showmaster Mini for step based tasks only The connectors for Showmaster Mini are all on th...

Страница 8: ...rs video servers sound processors etc Showmaster Pro also provides digital I O and balanced timecode input output with video reference Its editing software Medialon Manager 7 1 embeds most of the feat...

Страница 9: ...ock mount carrier for high vibration high shock environments The front panel includes the power button a USB 2 0 type A connector and a USB 3 0 type C connector The rear panel has four DisplayPort out...

Страница 10: ...he Devices send command orders using a Medialon plug in MxM through the appropriate resources MRC to connected machines Programming Mode Programming is done in Stop mode using either an offline versio...

Страница 11: ...wmaster Mini This has the Phoenix DC power connector and 3 5 mm mini jack sockets for line out and mic in 2 2 5 Mounting The rear panel has 3 screw points for attaching a DIN rail bracket for vertical...

Страница 12: ...disk 0 45 C 32 113 F with airflow rate 0 7 m sec Relative Humidity 95 40 C non condensing Storage Temperature 40 85 C 40 185 F Vibration Tolerance When the system is equipped with an SSD mSATA 3 Grms...

Страница 13: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re...

Страница 14: ...t power Medialon Showmaster LED Status Messages Four LEDs give a quick overview of the main status of Medialon Showmaster PWR Power LED This LED lights red when Showmaster is powered on SSD SSD LED Th...

Страница 15: ...Rear Panel The image below shows the rear panel of Medialon Showmaster LE LAN RJ45 Ethernet LAN connectors 10 100 1000 Base T USB Not used Serial 1 Serial Port 1 Serial RS232 port Serial 2 Serial Por...

Страница 16: ...wmaster LE via terminal block connectors Relay Output Connector Showmaster LE has four relays Relay outputs are connected to Showmaster LE via 4 terminal block connectors MIDI Connection Medialon Show...

Страница 17: ...kely to occur to the internal components Adequate clearance for airflow should be provided on both sides so ambient temperature does not exceed the limit Please refer to document M562 Medialon Safety...

Страница 18: ...s Number 2 Connector USB slave socket Interface USB 2 0 USB Top Port Not Used USB Bottom Port May be used for maintenance purposes such as image updates restoration Serial Interfaces Number 2 Connecto...

Страница 19: ...5 kg Operating Temperature 32 F 104 F 0 C 40 C Storage Temperature 4 F 185 F 20 C 85 C Operating Humidity 10 80 RH Non condensing Storage Humidity 5 90 RH Non condensing Operating Altitude sea level t...

Страница 20: ...ipment in a residential area may cause harmful interference in which case the user will be responsible for correcting any interference at their own expense Changes or modifications not expressly appro...

Страница 21: ...d 2 4 2 First Start Medialon Showmaster Pro is designed as a stand alone Show Controller Showmaster Pro does not need a keyboard mouse or screen to work Rear power switch must be set on all the time C...

Страница 22: ...tton for more than 4 seconds while the Showmaster Pro is powered on to reset it Cancel button Hold this button for more than 4 seconds to power off soft power Showmaster Pro Up arrow Scrolls display u...

Страница 23: ...ot yet running o Running Showmaster is running o Programming a project is being edited or tested o Debugging Manager is in debug mode a user is editing the project o License Missing the unit s license...

Страница 24: ...OFF OFF OFF Showmaster Starting Up Shutting Down ON OFF OFF Showmaster Ready OS ON OFF OFF Showmaster Project Starting ON ON OFF Showmaster in Running Mode ON ON OFF Showmaster in Programming Mode ON...

Страница 25: ...nical 1A relays Digital Inputs Digital Input Port 16 optically isolated inputs POWER Power Connector 12 V DC 5 A See Power section for details Digital Input Output Port Wiring Digital Input Connector...

Страница 26: ...A 16 Isolated Input 4B 23 Isolated Input 10B 29 Isolated Input 16B 35 Isolated Input 5A 5 Isolated Input 11A 11 No Connection 17 Isolated Input 5B 24 Isolated Input 11B 30 No Connection 36 Isolated In...

Страница 27: ...16 NO 35 Relay 4 Common 4 Relay 10 Common 10 Relay 16 Common 16 Relay 5 NO 24 Relay 11 NO 30 No Connection 17 Relay 5 Common 5 Relay 11 Common 11 No Connection 18 Relay 6 NO 25 Relay 12 NO 31 No Conne...

Страница 28: ...utput port Pin Connection 1 Cable shield 2 Signal 3 Signal Serial Connection Medialon Showmaster V2 Pro is provided with 8 serial ports Showmaster Pro is configured with DTE serial ports Use a crossov...

Страница 29: ...ing four sink head screws Using a Phillips screwdriver mount the device in the rack using four rack mounting screws 2 4 6 Technical Specifications Network Connection Number 2 Connector RJ45 female Int...

Страница 30: ...ing Voltage 125 V AC 60 V DC Max Switching Current 1 A Contact Resistance 100 m max Contact Life 5 million operations min Operating Time 5 mS max Release Time 5 mS max Connector Sub D 37 type Female W...

Страница 31: ...25 3 5 441 260 89 mm Weight 11 lbs 5 kg Operating Temperature 32 F 104 F 0 C 40 C Storage Temperature 4 F 185 F 20 C 85 C Operating Humidity 10 80 RH Non condensing Storage Humidity 5 90 RH Non conden...

Страница 32: ...eir own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC responsible 7thSense Design Ltd 420...

Страница 33: ...the whole 16 relays 2 5 Showmaster Go Description 2 5 1 Contents of the Package The Medialon Showmaster Go Package includes Medialon Showmaster Go Power adaptor 2 5 2 Getting Started Showmaster Go ru...

Страница 34: ...Panel The image below shows the rear panel of Medialon Showmaster Go Kingston safe lock 12 19 VDC power inlet with cable inlet clip 4 DisplayPort 1 2 3 opto isolated 0 3 5 V TTL 2 RJ45 10 100 1000 bas...

Страница 35: ...ports 3 USB 2 0 Type A 1 USB 3 1 Type C Power connection 12 19 VDC 60 watts max DC power inlet clip Ethernet 2 10 100 1000 base T Video output 4 DisplayPort 1 2 GPIO 3 opto isolated 0 3 5 V TTL Mounti...

Страница 36: ...n dust free area e g a server room The unit is intended for operation in benign environments that is not subject to corrosive or explosive atmospheres moisture or flammable gases The unit is non prote...

Страница 37: ...instructions Warning Do not operate the unit with any covers removed as the air flow through the unit may be compromised leading to overheating Any alterations to the product s specification includin...

Страница 38: ...ies covered by the European Directive which must be collected and disposed of separately from municipal waste If the battery contains more than the specified values of lead Pb mercury Hg or cadmium Cd...

Страница 39: ...t Delete the current project No DMX signal Check that the DMX cable is plugged in Check DMX sending No MIDI signal Check that the MIDI cable is plugged in for Showmaster V2 ST Check MIDI sending recei...

Страница 40: ...r User Manual p 38 of 42 M569 3 June 2023 Contact Us Find more on our website https 7thSense one and on social media For documentation visit https portal 7thSense one or contact our support team at su...

Страница 41: ...Medialon Showmaster User Manual p 39 of 42 M569 3 June 2023...

Страница 42: ...Steyning West Sussex BN44 3TN UK T 44 0 1903 812299 7thSense LLC Michigan 332 E Lincoln Ave Suite 100 Royal Oak MI 48067 USA T 1 248 599 2717 E info 7thsense one W 7thsense one 7thSense LLC Orlando 4...

Отзывы: